Measure the resistance between the following:ROOF OPENING PANEL SWITCH RESISTANCE SPECIFICATIONS
| Roof Opening Panel Switch Position |
Pins |
Measurement |
| Neutral |
1 -5 |
Greater than 10,000 ohms |
| Neutral |
2-6 |
Greater than 10,000 ohms |
| Neutral |
5 -6 |
Greater than 10,000 ohms |
| Neutral |
6- 1 |
Greater than 10,000 ohms |
| Fully Up/Close |
5 -6 |
Less than 100 ohms |
| Fully Up/Close |
5 - 1 |
Greater than 10,000 ohms |
| Fully Up/Close |
5 -2 |
Less than 100 ohms |
| Fully Up/Close |
2-6 |
Less than 100 ohms |
| Fully Down/Open |
2-6 |
Less than 100 ohms |
| Fully Down/Open |
2-5 |
Less than 100 ohms |
| Fully Down/Open |
5 -6 |
Less than 100 ohms |
| Fully Down/Open |
2- 1 |
Greater than 10,000 ohms |