Liftgate Lock Cylinder: Installation
- Using an M6 tap, cut a thread into the lock cylinder housing.
- Install the liftgate lock cylinder.
- Install the plunger.
- Install an M6 by 6.5 mm (0.25 in) screw to secure the plunger.
- Install the liftgate latch. For additional information, refer to LIFTGATE LATCH in this article.
NOTE:
Use Theadlock 262 on the top 2 threads below the screw head.