LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2006 >> Escape Hybrid, FWD >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 42 (Engine Controls - Pinpoint Test KE: Idle Air Control (IAC) Valve Through Pinpoint Test Z: Intermittent - (Except Diesel & Hybrid)) >> Pinpoint Test KF: Fan Control (FC) Relays >> Introduction >> Three Speed Fan Operation

Three Speed Fan Operation

WARNING: This page is about a different variant/trim than selected.

Although the PCM output circuits are called low, medium and high fan control (FC), cooling fan operation is controlled by a combination of these outputs.

Refer to ENGINE CONTROL COMPONENTS .

Fig 1: Low Fan Control (LFC) Relay Connector
G04587260Courtesy of FORD MOTOR CO.
NOTE: The VPWR and LFC circuits may be reversed in the harness connector. Also, the LFC circuit may be wired to 2 separate relays. Refer to the appropriate SYSTEM WIRING DIAGRAMS for additional information.
Fig 2: Medium Fan Control (MFC) Relay Connector
G04587261Courtesy of FORD MOTOR CO.
NOTE: The VPWR and MFC circuits may be reversed in the harness connector. Also, the MFC circuit may be wired to 2 separate relays. Refer to the appropriate SYSTEM WIRING DIAGRAMS for additional information.
Fig 3: High Fan Control (HFC) Relay Connector
G04587262Courtesy of FORD MOTOR CO.
NOTE: The VPWR and HFC circuits may be reversed in the harness connector. Also, the HFC circuit may be wired to 2 separate relays. Refer to the appropriate SYSTEM WIRING DIAGRAMS for additional information.