LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2005 >> Freestyle Limited, FWD >> Repair and Diagnosis >> Accessories & Equipment >> Gauges & Instrument Panels >> Instrument Cluster System >> Diagnosis And Testing >> Instrument Cluster >> Pinpoint Test R: The Speed Control Indicator Is Never/Always On >> Testing

Pinpoint Test R: The Speed Control Indicator Is Never/Always On: Testing

  1. R1 CHECK THE SPEED CONTROL OPERATION 
    • Test drive the vehicle and operate the speed control.
    • Does the speed control operate correctly? 
    • Yes  : GO to R2.
    • No  : REFER to SPEED CONTROL to continue diagnosis of the speed control system.
  2. R2 CARRY OUT THE INSTRUMENT CLUSTER SPEED CONTROL ACTIVE COMMAND USING THE DIAGNOSTIC TOOL 
    • Enter the following diagnostic mode on the scan tool: Instrument Cluster Active Command.
    • Select the instrument cluster warning lamps and chime active command. Trigger the all lamps active command on and off. Observe the speed control indicator.
    • Does the speed control indicator illuminate when triggered on and turn off when triggered off? 
    • Yes  : GO to R3.
    • No  : GO to  R4.
  3. R3 CHECK FOR CORRECT PCM OPERATION 
    • Disconnect all the PCM connectors.
    • Check for:
      • corrosion
      • pushed-out pins
    • Connect all the PCM connectors and make sure they seat correctly.
    • Operate the system and verify the concern is still present.
    • Is the concern still present? 
    • Yes  : INSTALL a new PCM. REFER to ELECTRONIC ENGINE CONTROLS . TEST the system for normal operation.
    • No  : The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector.
  4. R4 CHECK FOR CORRECT INSTRUMENT CLUSTER OPERATION 
    • Disconnect the instrument cluster connector.
    • Check for:
      • corrosion
      • pushed-out pins
    • Connect the instrument cluster connector and make sure it seats correctly.
    • Operate the system and verify the concern is still present.
    • Is the concern still present? 
    • Yes  : INSTALL a new instrument cluster. REFER to INSTRUMENT CLUSTER . TEST the system for normal operation.
    • No  : The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector.