Pinpoint Test J: The Malfunction Indicator Lamp (MIL) Is Never On: Testing
- J1 CARRY OUT THE INSTRUMENT CLUSTER WARNING LAMPS AND CHIME ACTIVE COMMAND USING THE DIAGNOSTIC TOOL
- Key in ON position.
- Enter the following diagnostic mode on the scan tool: Instrument Cluster Active Command.
- Select the instrument cluster warning lamps and chime active command. Trigger the all lamps active command on and off. Observe the MIL indicator.
- Does the MIL indicator illuminate when triggered on?
- Yes
: GO to J3.
- No
: GO to J2.
- J2 CHECK FOR CORRECT INSTRUMENT CLUSTER OPERATION
- Disconnect the instrument cluster connector.
- Check for:
- corrosion
- pushed-out pins
- Connect the instrument cluster connector and make sure it seats correctly.
- Operate the system and verify the concern is still present.
- Is the concern still present?
- Yes
: INSTALL a new instrument cluster. REFER to INSTRUMENT CLUSTER . TEST the system for normal operation.
- No
: The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector.
- J3 CHECK FOR CORRECT PCM OPERATION
- Disconnect all the PCM connectors.
- Check for:
- corrosion
- pushed-out pins
- Connect all the PCM connectors and make sure they seat correctly.
- Operate the system and verify the concern is still present.
- Is the concern still present?
- Yes
: INSTALL a new PCM. REFER to ELECTRONIC ENGINE CONTROLS
. TEST the system for normal operation.
- No
: The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector.