LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2005 >> Freestar Base >> Repair and Diagnosis >> Accessories & Equipment >> Cruise Control Systems >> Diagnosis And Testing >> Speed Control >> Pinpoint Tests >> Pinpoint Test C: The Speed Control Is Inoperative - No DTCs >> Pinpoint Test C: The Speed Control Is Inoperative - No DTCS

Pinpoint Test C: The Speed Control Is Inoperative - No DTCS

  1. C1 CHECK THE HORN SYSTEM 
    • Verify the horn system operates by pressing the horn switch.
    • Does the horn system operate correctly? 
    • Yes  : GO to C2  .
    • No  : REFER to HORN to continue diagnosis of the horn.
  2. C2 CHECK THE SPEED CONTROL ON SWITCH 
    • Key in OFF position.
    • Disconnect: Speed Control Actuator C122.
    • Key in ON position.
    • Measure the voltage between the speed control actuator C122-5, circuit 151 (LB/BK), harness side and ground while pressing the speed control ON switch.
      Fig 1: Measuring Voltage Between Speed Control Actuator C122-5, Circuit 151 (LB/BK), Harness Side And Ground
      G04016501Courtesy of FORD MOTOR CO.
    • Is the voltage greater than 10 volts? 
    • Yes  : GO to C3  .
    • No  : GO to  C4.
  3. C3 CHECK THE SET/ACCEL SWITCH 
    • Key in OFF position.
    • Measure the resistance between the speed control actuator C122-5, circuit 151 (LB/BK), harness side and the speed control actuator C122-6, circuit 848 (DG/OG), harness side while pressing the speed control SET/ACCEL switch.
      Fig 2: Measuring Resistance Between Speed Control Actuator C122-5 And Speed Control Actuator C122-6, Circuit 848
      G04016502Courtesy of FORD MOTOR CO.
    • Is the resistance between 612-748 ohms with the switch pressed and greater than 10,000 ohms with the switch released? 
  4. C4 CHECK CIRCUIT 151 (LB/BK) FOR AN OPEN 
    • Disconnect: Clockspring C218b.
    • Measure the resistance between the speed control actuator C122-5, circuit 151 (LB/BK), harness side and the clockspring C218b-6, circuit 151 (LB/BK), harness side.
      Fig 3: Measuring Resistance Between Speed Control Actuator C122-5 And Clockspring C218b-6
      G03957693Courtesy of FORD MOTOR CO.
    • Is the resistance less than 5 ohms? 
    • Yes  : GO to C5  .
    • No  : REPAIR the circuit. TEST the system for normal operation.
  5. C5 CHECK THE CLOCKSPRING 
    • Measure the resistance between the clockspring C218b-6, component side and the upper clockspring pin 1, component side.
      Fig 4: Measuring Resistance Between Clockspring C218b-6, Component Side And Upper Clockspring Pin 1, Component Side
      G04016504Courtesy of FORD MOTOR CO.
    • Is the resistance less than 5 ohms? 
  6. C6 CHECK CIRCUIT 601 (LB/PK) AND CIRCUIT 535 (LB/RD) FOR VOLTAGE 
    • Key in ON position.
    • Measure the voltage between the speed control actuator C122-7, circuit 601 (LB/PK), harness side and ground; and between the speed control actuator C122-9, circuit 535 (LB/RD), harness side and ground.
      Fig 5: Measuring Voltage Between Speed Control Actuator C122-7, Circuit 601 (LB/PK), Harness Side And Ground
      G04016505Courtesy of FORD MOTOR CO.
    • Are the voltages greater than 10 volts? 
    • Yes  : GO to C7  .
    • No  : REPAIR the circuit in question. TEST the system for normal operation.
  7. C7 CHECK CIRCUIT 1205 (BK) FOR AN OPEN 
    • Key in OFF position.
    • Measure the resistance between the speed control actuator C122-10, circuit 1205 (BK), harness side and ground.
      Fig 6: Measuring Resistance Between Speed Control Actuator C122-10, Circuit 1205 (BK), Harness Side And Ground
      G04016500Courtesy of FORD MOTOR CO.
    • Is the resistance less than 5 ohms? 
    • Yes  : GO to C8  .
    • No  : REPAIR the circuit. TEST the system for normal operation.
  8. C8 CHECK FOR CORRECT SPEED CONTROL ACTUATOR OPERATION 
    • Disconnect the speed control actuator connector.
    • Check for:
      • corrosion
      • pushed-out pins
    • Connect the speed control actuator connector and make sure it seats correctly.
    • Operate the system and verify the concern is still present.
    • Is the concern still present? 
    • Yes  : INSTALL a new speed control actuator. REFER to SPEED CONTROL ACTUATOR . TEST the system for normal operation.
    • No  : The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector.