LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2005 >> Focus ZX5 S, Automatic >> Repair and Diagnosis >> Body & Frame >> Sun Roof/T-Top/Convertible Top >> Sunroof >> General Procedures >> Roof Opening Panel Motor Initialization >> Updating Roof Opening Panel Motor Initialization

Updating Roof Opening Panel Motor Initialization

WARNING: The roof opening panel anti-trap function will not operate during the updating roof opening panel motor initialization procedure. Make sure that the roof opening panel opening is free of all foreign material. Failure to follow this instruction may result in personal injury.
NOTE: This procedure should only be carried out when the roof opening panel motor has not been disconnected.
NOTE: The roof opening panel alignment must be carried out prior to carrying out roof opening panel motor initialization. For additional information, REFER to ROOF OPENING PANEL ALIGNMENT .
  1. Operate the roof opening panel control switch to the up/close position until the roof opening panel is in the fully open/vent position.
  2. Release the roof opening panel control switch.
  3. Operate the roof opening panel control switch to the up/close position and hold for 30 seconds until there is a small movement (approximately 2 mm) and the roof opening panel motor stops.
  4. Release the roof opening panel control switch.
  5. Operate the roof opening panel control switch to the up/close position again within 0.5 seconds until the roof opening panel stops (one complete cycle).