Pinpoint Test E: A Single Power Window Is Inoperative, RH Front - Zephyr
- E1 CHECK THE LH FRONT WINDOW CONTROL SWITCH OPERATION
- Attempt to operate the RH window using the LH front power window control switch.
- Does the RH window operate when using the LH front power window control switch?
Yes : GO to E6.
No : GO to E2.
- E2 CHECK THE POWER TO THE WINDOW MOTOR
- Key in OFF position.
- Disconnect: RH Front Window Motor C623.
- Measure the voltage between RH front window motor C623-4, circuit SBB35 (BU/RD), harness side and ground.
- Is the voltage greater than 10 volts?
Yes : GO to E3.
No : VERIFY BJB fuse 35 (30A) is OK. If OK, REPAIR the circuit. DE-INITIALIZE, then INITIALIZE the RH front window motor. REFER to WINDOW MOTOR INITIALIZATION . TEST the system for normal operation.
- E3 CHECK THE RH FRONT WINDOW MOTOR GROUND
- Measure the resistance between RH front window motor C623-3, circuit GD139 (BK/YE), harness side and ground.
- Is the resistance less than 5 ohms?
Yes : GO to E4.
No : REPAIR the circuit. DE-INITIALIZE, then INITIALIZE the RH front window motor. REFER to WINDOW MOTOR INITIALIZATION . TEST the system for normal operation.
- E4 CHECK THE LH FRONT WINDOW CONTROL SWITCH-TO-RH FRONT WINDOW MOTOR FEEDS
- Disconnect: LH Front Window Control Switch C535A. Measure the resistance between RH front window motor C623-1, circuit CPW12 (GN/OG), harness side and LH front window control switch C535A-2, circuit CPW12 (GN/OG), harness side.
- Measure the resistance between RH front window motor C623-5, circuit CPW31 (GN/WH), harness side and LH front window control switch C535A-1, circuit CPW31 (GN/WH), harness side.
- Measure the resistance between RH front window motor C623-6, circuit CPW13 (BN/YE), harness side and LH front window control switch C535A-5, circuit CPW13 (BN/YE), harness side.
- Are the resistances less than 5 ohms?
Yes : GO to E5.
No : REPAIR the circuit. DE-INITIALIZE, then INITIALIZE the RH front window motor. REFER to WINDOW MOTOR INITIALIZATION . TEST the system for normal operation.
- E5 CHECK THE LH FRONT WINDOW CONTROL SWITCH
- Carry out the LH front window control switch component test. Refer to COMPONENT TESTING .
- Did the window control switch pass the component test?
Yes : INSTALL a new RH front window motor. REFER to GLASS, FRAMES AND MECHANISMS - EXPLODED VIEW, FRONT DOOR and WINDOW REGULATOR AND MOTOR - FRONT DOOR . INITIALIZE the RH front window motor. REFER to WINDOW MOTOR INITIALIZATION . TEST the system for normal operation.
No : INSTALL a new LH front window control switch. REFER to WINDOW CONTROL SWITCH . INITIALIZE the RH front window motor. REFER to WINDOW MOTOR INITIALIZATION . TEST the system for normal operation.
- E6 CHECK CIRCUIT CBP02 (GN) FOR VOLTAGE
- Disconnect: RH Front Window Control Switch C604.
- Key in ON position.
- Measure the voltage between RH front window control switch C604-2, circuit CBP02 (GN), harness side and ground.
- Is the voltage greater than 10 volts?
Yes : GO to E7.
No : REPAIR the circuit. TEST the system for normal operation.
- E7 CHECK THE LH FRONT WINDOW CONTROL SWITCH-TO-RH FRONT WINDOW CONTROL SWITCH CIRCUITS
- Key in OFF position.
- Disconnect: LH Front Window Control Switch C535A.
- Measure the resistance between RH front window control switch C604-5, circuit CPW12 (GN/OG), harness side and LH front window control switch C535A-2, circuit CPW12 (GN/OG), harness side.
- Measure the resistance between RH front window control switch C604-4, circuit CPW31 (GN/WH), harness side and LH front window control switch C535A-1, circuit CPW31 (GN/WH), harness side.
- Measure the resistance between RH front window control switch C604-3, circuit CPW13 (BN/YE), harness side and LH front window control switch C535A-5, circuit CPW13 (BN/YE), harness side.
- Are the resistances less than 5 ohms?
Yes : INSTALL a new RH front window control switch. REFER to WINDOW CONTROL SWITCH . TEST the system for normal operation.
No : REPAIR the circuit. TEST the system for normal operation.