Pinpoint Test BJ: DTC U0111:00
WARNING: This page is about a different car, the 2011 Mercury Milan, 2011 Lincoln MKZ, and 2011 Ford Fusion. However, it is still accessible from the selected car via links, so may be relevant.
- BJ1 VERIFY THE CUSTOMER CONCERN
- Ignition ON.
- Verify that there is an observable symptom present.
- Is an observable symptom present?
- Yes : GO to BJ2.
- No : The system is operating normally at this time. The DTC may have been set due to high network traffic or an intermittent fault condition.
- BJ2 CHECK THE COMMUNICATION NETWORK
- Ignition ON.
- Enter the following diagnostic mode on the scan tool: Network Test.
- Carry out the network test.
- Does the BPSM pass the network test?
- Yes : GO to BJ3.
- No : REFER to MODULE COMMUNICATIONS NETWORK -- FUSION, MILAN & MKZ article.
- BJ3 RETRIEVE THE RECORDED DTCs FROM THE IPC SELF-TEST
- Check for recorded DTCs from the IPC self-test.
- Is DTC U3003:16 or DTC U3003:17 recorded?
- Yes : GO to PINPOINT TEST BX (U3003:16) or GO to PINPOINT TEST BY (U3003:17).
- No : GO to BJ4.
- BJ4 RECHECK THE IPC DTCs NOTE: If new modules were installed prior to the DTC being set, the module configuration may be incorrectly set during the Programmable Module Installation (PMI) or the PMI may not have been carried out.
- Clear the DTCs. Repeat the IPC self-test.
- Is DTC U0111:00 still present?
- Yes : GO to BJ5.
- No : The system is operating correctly at this time. The DTC may have been set due to high network traffic or an intermittent fault condition.
- BJ5 CHECK FOR DTC U0111 SET IN OTHER MODULES
- Clear all DTCs.
- Ignition OFF.
- Ignition ON.
- Wait 10 seconds.
- Enter the following diagnostic mode on the scan tool: Self-Test.
- Retrieve the continuous memory DTCs from all modules.
- Is DTC U0111 set in the PCM?
- Yes : INSTALL a new BPSM. REFER to HIGH VOLTAGE TRACTION BATTERY -- FUSION HYBRID, MILAN HYBRID & MKZ HYBRID article. CLEAR the DTCs. REPEAT the self-test.
- No : INSTALL a new IPC . REFER to INSTRUMENT PANEL CLUSTER (IPC) in this service information. TEST the system for normal operation.