Normal Operation
When the low to high shift occurs, circuit 782 (BR/WH) provides the 4X4 control module-switched ground path for the clockwise rotation relay. While the low to high (clockwise) relay is energized, circuit 777 (YE) sends battery voltage from the battery junction box (BJB) fuse 3 (30A) and circuit 704 (DG/LG). Circuit 778 (OG) provides ground for the transfer case shift motor to operate in the clockwise direction. When the high to low shift occurs, circuit 781 (OG/LB) provides the 4X4 control module-switched ground path for the counterclockwise rotation relay. While the high to low counterclockwise relay is energized, circuit 778 (OG) sends battery voltage from the battery junction box (BJB) fuse 3 (30A) and circuit 704 (DG/LG). Circuit 777 (YE) provides ground for the transfer case shift motor to operate in the counterclockwise direction.
Possible Causes
- Battery junction box fuse 3 (30A)
- Circuits:
- 704 (DG/LG)
- 57a (BK)
- 57b (BK)
- 777 (YE)
- 778 (OG)
- 781 (OG/LB)
- 782 (BN/WH)
- Low to high (clockwise) relay
- High to low (counterclockwise) relay