LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2005 >> Escape Base, 3.0 1, FWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 465 (Exterior Lighting System) >> Diagnosis And Testing >> Trailer Lamps >> Pinpoint Tests >> Pinpoint Test Z: The Trailer Lamps Are On Continuously >> Pinpoint Test Z: The Trailer Lamps Are On Continuously

Pinpoint Test Z: The Trailer Lamps Are On Continuously

WARNING: This page is about a different car, the 2006 Mercury Mariner and 2006 Ford Escape. However, it is still accessible from the selected car via links, so may be relevant.
  1. Z1 CHECK THE CIRCUITRY FOR SHORTS TO VOLTAGE 
    • Key in OFF position.
    • Disconnect: Trailer Tow C439.
    • Key in ON position.
    • Measure the voltage between the trailer tow C439, harness side and ground as follows:
      TRAILER TOW CONNECTOR-PIN REFERENCE

      Connector-Pin Circuit
      C439-1 64 (DG)
      C439-2 52 (YE)
      C439-3 962 (BN/WH)
    • Is any voltage present? 

    Yes:  GO to  Z2.

    No:  The vehicle is operating correctly. SEND the trailer to an authorized camper/trailer repair center.

  2. Z2 CHECK THE SJB 
    • Key in OFF position.
    • Disconnect: SJB C2280c.
    • Key in ON position.
    • Measure the voltage between the trailer tow C439, harness side and ground as follows:
      TRAILER TOW CONNECTOR-PIN REFERENCE

      Connector-Pin Circuit
      C439-1 64 (DG)
      C439-2 52 (YE)
      C439-3 962 (BN/WH)
    • Is any voltage present? 

    Yes:  REPAIR the circuit in question. TEST the system for normal operation.

    No:  GO to  Z3.

  3. Z3 CHECK FOR CORRECT SJB OPERATION 
    • Disconnect all the SJB connectors.
    • Check for:
      • corrosion
      • pushed-out pins
    • Connect all the SJB connectors and make sure they seat correctly.
    • Operate the system and verify the concern is still present.
    • Is the concern still present? 

    Yes:  INSTALL a new SJB. REFER to SMART JUNCTION BOX (SJB) . TEST the system for normal operation.

    No:  The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector.