DTC P0041: Downstream Oxygen Sensors Swapped from Bank to Bank (HO2S-12-22)
P0041 - DOWNSTREAM OXYGEN SENSORS SWAPPED FROM BANK TO BANK (HO2S-12-22)
| Description: | The heated oxygen sensor (HO2S) monitor determines if the HO2S signal response for a fuel shift corresponds to the correct engine bank. The test fails when a response from the HO2S being tested is not indicated. | ||
| Possible Causes: |
|
||
| Diagnostic Aids: | Connect the HO2S connector to the correct bank. | ||
| Application | Key On Engine Off | Key On Engine Running | Continuous Memory |
| All | - | GO to H: Fuel Control STEP H60. | - |