LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2004 >> Thunderbird >> Repair and Diagnosis >> Accessories & Equipment >> Gauges & Instrument Panels >> Information, Gauges & Warning Devices >> Diagnosis And Testing >> Horn >> Symptom Chart

Symptom Chart

SYMPTOMS

Condition Possible Sources Action
  • No communication with the front electronic module (FEM)
  • Central junction box (CJB) fuses:
    • 20 (10A).
    • 30 (5A).
    • 33 (10A).
  • Battery junction box (BJB) fuse 20 (30A).
  • Circuitry.
  • J1850 standard corporate protocol (SCP) communication network.
  • FEM.
  • No communication with the instrument cluster module
  • Central junction box (CJB) fuses:
    • 4 (5A).
    • 13 (5A).
    • 17 (5A).
    • 20 (10A).
  • Circuitry.
  • J1850 standard corporate protocol (SCP) communication network.
  • Instrument cluster.
  • The horn is inoperative
  • Auxiliary junction box fuse 4 (15A).
  • Circuitry.
  • Horn relay.
  • Horn switch.
  • Horn.
  • Clockspring.
  • Front Electronic Module (FEM).
  • Instrument cluster.
  • The horn is always on
  • Instrument cluster.
  • Horn relay.
  • Circuitry.
  • Clockspring.
  • Horn switch.
  • Front Electronic Module (FEM).