Home >> Ford >> 2004 >> Excursion 6.8 S, RWD >> Repair and Diagnosis (Single Page) >> Engine Performance >> System >> Engine Controls - Powertrain DTC Charts & Descriptions - CNG, Flex-Fuel & Gasoline >> Diagnostic Trouble Code (DTC) Charts >> P0040: Upstream Oxygen Sensors Swapped From Bank To Bank (Ho2S-11-21)

P0040: Upstream Oxygen Sensors Swapped From Bank To Bank (Ho2S-11-21)

P0040 - UPSTREAM OXYGEN SENSORS SWAPPED FROM BANK TO BANK (HO2S-11-21)

Description:  The heated oxygen sensor (HO2S) monitor determines if the HO2S signal response for a fuel shift corresponds to the correct engine bank. The test fails when a response from the HO2S being tested is not indicated.
Possible Causes: 
  • Crossed HO2S harness connectors (upstream).
  • Crossed HO2S wiring at the harness connectors (upstream).
  • Crossed HO2S wiring at the 104-pin harness connectors (upstream).
Diagnostic Aids:  -
Application  Key On Engine Off  Key On Engine Running  Continuous Memory 
Dedicated NGV GO to PINPOINT TEST HA: NATURAL GAS FUEL CONTROL Step 52. GO to PINPOINT TEST HA: NATURAL GAS FUEL CONTROL Step 52 GO to PINPOINT TEST HA: NATURAL GAS FUEL CONTROL Step 52.
All others - GO to PINPOINT TEST H: FUEL CONTROL Step 69. -