Removal and Installation
- Partially drain the cooling system. Refer to COOLING SYSTEM DRAINING, FILLING AND BLEEDING .
- Squeeze the clamp and remove the overflow hose.
- Remove the bolts.
- Squeeze the clamp and remove the degas bottle supply hose.
- Remove the degas bottle.