Home >> Ford >> 2003 >> Cutaway 7.3 F >> Repair and Diagnosis >> External Pages >> Different car >> Section 2544 (Turbocharger Cooling System -- F250-F550 Super Duty) >> General Procedures >> Fuel and Turbocharger Cooling System Draining, Filling and Bleeding >> Filling and bleeding with RADIATOR REFILLER

Filling and bleeding with RADIATOR REFILLER

WARNING: This page is about a different car, the 2010 Ford Pickup, 2010 Ford F550 Super Duty, 2010 Ford F450 Super Duty, and 2010 Ford Cab & Chassis. However, it is still accessible from the selected car via links, so may be relevant.
  1. Assemble the RADIATOR REFILLER with the adapter nipple.
    Fig 1: Identifying Radiator Refiller (078-00592)
    G06778270Courtesy of FORD MOTOR CO.
  2. NOTE: With the system cold, fill vehicles to within the sight glass on the coolant expansion tank. This fill level will allow for coolant expansion. Overfilling the coolant expansion tank may result in damage to the pressure cap, which can cause the fuel and turbocharger cooling system to overheat.
    Fig 2: Filling Coolant With Radiator Refiller
    G06778271Courtesy of FORD MOTOR CO.
  3. Install the RADIATOR REFILLER and follow the RADIATOR REFILLER manufacturer's instructions to fill and bleed the cooling system.
  4. NOTE: An operating coolant pump that squeals indicates either:
    • the system is not completely filled or bled.
    • the coolant pump is bad and must be replaced.
  5. If the coolant pump squeals, drain the cooling system, fill and bleed the cooling system again.
    • If the coolant pump still squeals, replace the coolant pump. For addition information, refer to COOLANT PUMP .