Diagnostic Aids
Perform this test when instructed during QUICK TEST or if directed by other test procedures. This test is used to diagnose the exhaust system and downstream HO2S.
Internal damage of a catalytic converter is usually caused by abnormal engine operation upstream of catalyst. Conditions that produce higher than normal temperatures in the catalytic converter, such as cylinder misfire, are likely suspects.