Diagnostic Aids
Perform this test only when directed by QUICK TEST. This test is intended to diagnose the following:
- Air Conditioning Evaporative Temperature (ACET) Sensor
- Wiring Harness Circuits (ACET & SIG RTN)
- Powertrain Control Module (PCM)
DTC P1437 is set when ACET signal is more than self-test maximum of 4.5 volts. DTC P1436 is set when ACET signal is less than self-test minimum of .13 volt.
NOTE:
ACET sensor may also be referred to as an Evaporator Air Discharge Temperature (EADT) sensor.
ACET SENSOR SPECIFICATIONS (1)
| Temperature °F (°C) | Volts | Ohms | ||
|---|---|---|---|---|
| -4 (-20) | 4.66 | 276,960 | ||
| 14 (-10) | 4.45 | 160,310 | ||
| 32 (0) | 4.14 | 95,850 | ||
| 50 (10) | 3.73 | 58,990 | ||
| 68 (20) | 3.26 | 37,340 | ||
| 86 (30) | 2.74 | 24,250 | ||
| 104 (40) | 2.23 | 16,110 | ||
| 122 (50) | 1.77 | 10,930 | ||
| 140 (60) | 1.37 | 7550 | ||
| 158 (70) | 1.05 | 5340 | ||
| 176 (80) | .80 | 3840 | ||
| 194 (90) | .61 | 2800 | ||
| 212 (100) | .47 | 2080 | ||
|
||||