LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2002 >> ZX2 Automatic >> Repair and Diagnosis (Single Page) >> Engine Mechanical >> Cooling System (Mechanical) >> Engine Cooling System >> Removal And Installation >> Thermostat Housing - 2.0L Zetec-E (Zetec) >> Removal

Thermostat Housing - 2.0L Zetec-E (Zetec): Removal

  1. Drain the cooling system. For additional information, refer to COOLING SYSTEM DRAINING, FILLING AND BLEEDING .
  2. Disconnect the coolant hoses.
    Fig 1: Disconnecting Coolant Hoses
    G03433074Courtesy of FORD MOTOR CO.
  3. Remove the thermostat housing bolts.
    Fig 2: Removing Thermostat Housing Bolts
    G03433075Courtesy of FORD MOTOR CO.
  4. Remove the thermostat housing.
    1. Disconnect the coolant hose.
    2. Remove the thermostat housing.
      Fig 3: Removing Thermostat Housing
      G03433076Courtesy of FORD MOTOR CO.
  5. Remove and discard the O - ring seal.
    Fig 4: Removing And Discard O - Ring Seal
    G03433077Courtesy of FORD MOTOR CO.