LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2002 >> Taurus SES, 3.0 S >> Repair and Diagnosis >> External Pages >> Different car >> Section 976 (HVAC System - General Information -- Excursion & F250-F550 Super Duty) >> General Procedures >> Air Conditioning (A/C) System Recovery, Evacuation and Charging >> Refrigerant System Recovery

Refrigerant System Recovery

WARNING: This page is about a different car, the 2003 Ford Pickup, 2003 Ford F550 Super Duty, 2003 Ford F450 Super Duty, 2003 Ford Excursion, and 2003 Ford Cab & Chassis. However, it is still accessible from the selected car via links, so may be relevant.
NOTE: Ford Motor Company recommends use of an A/C service center to carry out recovery, evacuation, and charging of the refrigerant system. If an A/C service center is not available, refrigerant system recovery, evacuation, and charging may be accomplished using a separate recovery station, vacuum pump, charging cylinder, and manifold gauge set.
  1. Prior to recovering the refrigerant system, you must verify the purity of the refrigerant. Refer to REFRIGERANT IDENTIFICATION TESTING .
  2. NOTE: Some R-134a service centers require the use of an A/C manifold gauge set. Refer to MANIFOLD GAUGE SET CONNECTION .
  3. Connect an R-134a A/C service center to the low- and high-pressure service gauge port valves.
  4. Recover the refrigerant from the system following the operating instructions provided by the equipment manufacturer.
  5. Once the service center has recovered the vehicle A/C system refrigerant, close the service center inlet valve (if equipped). Then switch off the power supply.
  6. Allow the vehicle A/C system to remain closed for about two minutes. Observe the system vacuum level as shown on the gauge. If the vacuum does not decrease, disconnect the refrigerant center hose(s).
  7. If the system vacuum does decrease, repeat Steps  2 through 5 until the vacuum level remains stable for two minutes.
  8. Carry out the required repairs.