Battery Saver

WARNING: This page is about a different car, the 2003 Mercury Sable and 2003 Ford Taurus. However, it is still accessible from the selected car via links, so may be relevant.

The battery saver is activated when the GEM is not receiving voltage input from the ignition switch (off position). The GEM will then provide ground to the battery saver relay coil for a maximum of 30 minutes depending on the state of the interior lamp switch inputs to the GEM. The energized battery saver relay switches voltage to the demand lamp circuit and the interior lamp relay coil. After time-out, the GEM removes ground to the battery saver relay disabling the demand lamp circuit.