LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2002 >> Taurus SES, 3.0 S >> Repair and Diagnosis >> External Pages >> Different car >> Section 419 (HVAC System - Air Conditioning -- Excursion & F250-F550 Super Duty) >> Description And Operation >> Air Conditioning >> Refrigerant System Dye

Refrigerant System Dye

WARNING: This page is about a different car, the 2003 Ford Pickup, 2003 Ford F550 Super Duty, 2003 Ford F450 Super Duty, and 2003 Ford Excursion. However, it is still accessible from the selected car via links, so may be relevant.

Fluorescent refrigerant system dye is added to the refrigerant system at the factory to assist in refrigerant system leak diagnosis using a Rotunda approved ultraviolet blacklight. It is not necessary to add additional dye to the refrigerant system before diagnosing leaks, even if a significant amount of refrigerant has been removed from the system. Replacement suction accumulators are shipped with a fluorescent dye "wafer" included in the desiccant bag, which will dissolve after approximately 30 minutes of continued A/C operation. It is not necessary to add dye after flushing or filtering the refrigerant system because a new suction accumulator is installed as part of the flushing or filtering procedure. Additional refrigerant system dye should only be added if more than 50% of the refrigerant system lubricant capacity has been lost due to a fitting separation, hose rupture, etc. Refer to CLIMATE CONTROL SYSTEM - GENERAL INFORMATION .