  1. Disconnect negative battery cable. Remove air cleaner assembly and air cleaner outlet tube. Remove accelerator cable shield. See Figure.
  2. Disconnect accelerator cable, speed control actuator cable and throttle return spring from throttle body. See Figure. Remove bolts, then position accelerator cable bracket aside. See Figure.
  3. Disconnect Evaporative Emissions (EVAP) return tube and vacuum hose. See Figure. Disconnect Idle Air Control (IAC) valve and Throttle Position (TP) sensor electrical connectors. See Figure.
  4. Disconnect wiring harness from intake manifold support bracket. See Figure. Remove upper intake manifold support bracket. See Figure.
  5. Disconnect Positive Crankcase Ventilation (PCV) tube from upper intake manifold. See Figure. Disconnect Exhaust Gas Recirculation (EGR) tube and vacuum hose from EGR valve. See Figure.
  6. Disconnect vacuum regulator solenoid vacuum and electrical connections. Disconnect vacuum hose from upper intake manifold. See Figure.
  7. Disconnect wiring harness retaining clip. Disconnect spark plug wire retainer and radio interference capacitor electrical connector. See Figure.
  8. Remove bolts retaining upper intake manifold and remove upper intake manifold.