LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2002 >> Focus SVT >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> HVAC Systems - General Servicing >> Recovery/Evacuation & Recharging >> Ford Motor Co. >> Refrigerant System Recovery

Refrigerant System Recovery

  1. Prior to recovering refrigerant system, verify purity of refrigerant using Refrigerant Identifier/Air-Radicator (198-00003) or equivalent. Refer to operating instructions supplied by equipment manufacturer for proper care and use of this equipment.
  2. NOTE: Some R-134a service centers require the use of an A/C manifold gauge set.
  3. Connect an R-134a A/C service center to low and high pressure service gauge port valves.
  4. Recover refrigerant from system following operating instructions provided by equipment manufacturer.
  5. Once service center has recovered vehicle A/C system refrigerant, close service center inlet valve (if equipped). Then turn off power supply.
  6. Allow vehicle A/C system to remain closed for about 2 minutes. Observe system vacuum level as shown on gauge. If vacuum does not decrease, disconnect refrigerant center hose(s).
  7. If system vacuum does decrease, repeat steps  2- 5 until vacuum level remains stable for 2 minutes.
  8. Carry out required repairs.