Test C: Oil Pressure Gauge Inaccurate
NOTE:
Ensure engine oil level is correct. Verify oil pressure switch Black 1-pin harness connector C103 is securely connected. A momentary drop in oil pressure is normal during hard braking.
- Turn ignition switch to ON position. If oil pressure gauge reads low, go to next step. If oil pressure gauge does not read low, go to step 5.
- Start engine. If oil pressure gauge reads in normal range, check for intermittent problem. If oil pressure gauge does not read in normal range, go to next step.
- Turn ignition switch to LOCK position. Disconnect instrument cluster White 16-pin harness connector C220a. Start engine. Measure resistance between instrument cluster White 16-pin harness connector C220a terminals No. 5 (Black/White wire) and No. 6 (White/Red wire). See Figure. If resistance is 5 ohms or more, go to next step. If resistance is less than 5 ohms, replace instrument cluster. See INSTRUMENT CLUSTER under REMOVAL & INSTALLATION. Retest system operation.
- Turn ignition switch to LOCK position. Disconnect oil pressure switch Black 1-pin harness connector C103. Connect a 10-amp fused jumper wire between ground and oil pressure switch Black 1-pin harness connector C103 terminal (White/Red wire). Measure resistance between ground and instrument cluster White 16-pin harness connector C220a terminal No. 6 (White/Red wire). If resistance is less than 5 ohms, replace oil pressure switch. See appropriate article in ENGINES. If resistance is 5 ohms or more, repair open in White/Red wire. See WIRING DIAGRAMS . Retest system operation.
- Turn ignition switch to LOCK position. Disconnect instrument cluster White 16-pin harness connector C220a. Measure resistance between ground and instrument cluster White 16-pin harness connector C220a terminal No. 6 (White/Red wire). If resistance is less than 5 ohms, go to next step. If resistance is 5 ohms or more, replace instrument cluster. See INSTRUMENT CLUSTER under REMOVAL & INSTALLATION. Retest system operation.
- Disconnect oil pressure switch Black 1-pin harness connector C103. Measure resistance between ground and instrument cluster White 16-pin harness connector C220a terminal No. 6 (White/Red wire). If resistance is less than 5 ohms, repair short to ground in White/Red wire. See WIRING DIAGRAMS . Retest system operation. If resistance is 5 ohms or more, replace oil pressure switch. See appropriate article in ENGINES. Retest system operation.