Valve Clearance Adjustment
NOTE:
Hydraulic valve lifters are used. No valve adjustment is required. When valve and/or valve seat is machined, valve clearance is reduced and may cause improper valve operation. Different length push rods are available for correcting clearance. Valve lifter must be collapsed to check valve clearance.
- With valve cover removed, position piston No. 1 at TDC of compression stroke. Completely collapse cylinder No. 1 intake valve lifter and hold valve lifter collapsed. Using feeler gauge, measure clearance between rocker arm and valve stem.
- Clearance should be within specification. See COLLAPSED VALVE LIFTER CLEARANCE table. Replace push rod, if necessary, to obtain correct clearance.
- Position crankshaft as specified in VALVE CLEARANCE CHECKING SEQUENCE table, and check appropriate valves. Replace push rods if clearance is not within specification.
- If push rod(s) is replaced, ensure corresponding cylinder piston is below TDC. It will be necessary to loosen or remove rocker arm to replace push rod.
CAUTION:
DO NOT operate or crank engine after installing push rod until valve lifter has leaked down to normal operating position.
COLLAPSED VALVE LIFTER CLEARANCE
| Application | In. (mm) |
|---|---|
| Intake & Exhaust | .09-.19 (2.3-4.8) |
VALVE CLEARANCE CHECKING SEQUENCE
| Crankshaft Position (1) | Intake Valves | Exhaust Valves | ||
|---|---|---|---|---|
| Cyl. No. 1 At TDC | No. 1, 3 & 6 | No. 1, 2 & 4 | ||
| Rotate 360° | No. 2, 4 & 5 | No. 3, 5 & 6 | ||
|
||||