LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2000 >> ZX2 Automatic >> Repair and Diagnosis >> Accessories & Equipment >> Gauges & Instrument Panels >> Instrument Panels - Analog >> System Tests >> Test U: Improper Upshift Indicator Operation

Test U: Improper Upshift Indicator Operation

  1. Turn ignition off. Remove instrument cluster. See INSTRUMENT CLUSTER  under REMOVAL & INSTALLATION. Remove upshift indicator light bulb. Check continuity between terminals of bulb. If continuity exists, go to next step. If continuity does not exist, replace upshift indicator light bulb and retest system.
  2. Visually inspect instrument cluster printed circuit for damage, cracks or hot spots. If instrument cluster printed circuit is okay, see appropriate SELF-DIAGNOSTICS article in ENGINE PERFORMANCE to diagnose upshift indicator circuit. If instrument cluster printed circuit is damaged, replace printed circuit and gauge contact clips. See PRINTED CIRCUIT  under REMOVAL & INSTALLATION.