EPC Solenoid
CAUTION:
Transaxle damage will occur if stall test is conducted with EPC switch depressed.
Record line pressure. Maximum line pressure should be 84 psi (5.7 kg/cm2 ). If line pressure is not within specification, see TEST E under SYSTEM TESTS or PERFORMANCE TESTS in FORD AX4N OVERHAUL article. Depress EPC switch. Minimum line pressure should be 56 psi (3.9 kg/cm2 ). If line pressure is not within specification, see TEST E under SYSTEM TESTS or PERFORMANCE TESTS in FORD AX4N OVERHAUL article.