LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2000 >> Taurus LX, 3.0 2, AX4N >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> General Servicing >> HVAC System - General Servicing Procedures >> Orifice Tube Replacement >> General Motors >> Removal ("F" Body)

Removal ("F" Body)

Discharge A/C system, using approved recovery/recycling equipment. Disconnect negative battery cable. Disconnect A/C pressure switch connector. Use a back-up wrench to hold evaporator fitting, and loosen evaporator liquid line fitting. Remove bolt. Disconnect evaporator liquid line. Remove and discard "O" rings. Using needle-nose pliers, remove orifice tube from evaporator inlet line.