Home >> Ford >> 2000 >> Taurus LX, 3.0 2, AX4N >> Repair and Diagnosis >> External Pages >> Different car >> Section 806 (Warning Devices) >> Diagnosis And Testing >> Warning Devices >> Pinpoint Tests >> Pinpoint Test B: The Headlamps On Warning Chime Is Inoperative >> Pinpoint Test B: The Headlamps On Warning Chime Is Inoperative

Pinpoint Test B: The Headlamps On Warning Chime Is Inoperative

WARNING: This page is about a different car, the 2006 Mercury Milan, 2006 Lincoln Zephyr, and 2006 Ford Fusion. However, it is still accessible from the selected car via links, so may be relevant.
  1. B1 CHECK THE EXTERIOR LAMPS 
    • Turn the headlamp switch to the on position.
    • Do the parking lamps illuminate with the headlamp switch in the on position? 

    Yes  : GO to B2.

    No  : REFER to EXTERIOR LIGHTING to continue diagnosis of the exterior lamps.

  2. B2 CHECK THE DOOR AJAR INDICATOR 
    • Key in OFF position.
    • Disconnect the diagnostic tool.
    • Make sure all the doors are closed.
    • Key in ON position.
    • While observing the message center (if equipped) or the door ajar warning indicator, open the driver door.
    • Is the DRIVER DOOR AJAR message displayed on the message center (if equipped) or the door ajar warning indicator illuminated with the driver door open? 

    Yes  : GO to B3.

    No  : If not equipped with a message center, REFER to INSTRUMENT CLUSTER to continue diagnosis of the door ajar warning indicator.

    If equipped with a message center, REFER to INFORMATION AND MESSAGE CENTER to continue diagnosis of the message center.

  3. B3 CHECK THE INSTRUMENT CLUSTER ILLUMINATION FOR CORRECT OPERATION 
    • Turn the headlamp switch to the on position.
    • Does the instrument cluster illumination operate correctly? 

    Yes  : GO to B4.

    No  : REFER to INSTRUMENT CLUSTER AND PANEL ILLUMINATION to continue diagnosis of the instrument cluster illumination.

  4. B4 CHECK FOR CORRECT INSTRUMENT CLUSTER OPERATION 
    • Disconnect the instrument cluster connector.
    • Check for:
      • Corrosion
      • Pushed-out pins
    • Connect the instrument cluster connector and make sure it seats correctly.
    • Operate the system and verify the concern is still present.
    • Is the concern still present? 

    Yes  : INSTALL a new instrument cluster. REFER to INSTRUMENT CLUSTER . TEST the system for normal operation.

    No  : The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector.