LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2000 >> Taurus LX, 3.0 2, AX4N >> Repair and Diagnosis >> External Pages >> Different car >> Section 555 (Handles, Locks, Latches And Entry Systems) >> Diagnosis And Testing >> Locks, Latches and Entry Systems >> Inspection and Verification

Inspection and Verification

WARNING: This page is about a different car, the 2006 Mercury Mariner and 2006 Ford Escape. However, it is still accessible from the selected car via links, so may be relevant.
  1. Verify the customer concern.
  2. Visually inspect for obvious signs of mechanical or electrical damage.
    VISUAL INSPECTION CHART

    Mechanical Electrical
    • Latches
    • Battery junction box (BJB) fuse 2 (25A)
    • Smart junction box (SJB) fuse 9 (30A)
    • Circuitry
    • RKE transmitter
    • RKE keypad
    • Door lock control switch
    • SJB
  3. If an obvious cause for an observed or reported concern is found, correct the cause (if possible) before proceeding to the next step.
  4. If the cause is not visually evident, connect the diagnostic tool to the data link connector (DLC) and select the vehicle to be tested from the diagnostic tool menu. If the diagnostic tool does not communicate with the vehicle:
    • Check that the program card is correctly installed.
    • check the connections to the vehicle.
    • check the ignition switch position.
  5. If the diagnostic tool still does not communicate with the vehicle, refer to the diagnostic tool operating manual .
  6. Carry out the diagnostic tool data link test. If the diagnostic tool responds with:
    • CAN or ISO circuit fault; all electronic control units no response/not equipped, refer to MODULE COMMUNICATIONS NETWORK .
    • No response/not equipped for the SJB, refer to MULTIFUNCTION ELECTRONIC MODULES .
    • System passed, retrieve and record the continuous diagnostic trouble codes (DTCs), erase the continuous DTCs, and carry out the self-test diagnostics for the SJB.
  7. If the DTCs retrieved are related to the concern, go to the SMART JUNCTION BOX (SJB) DIAGNOSTIC TROUBLE CODE (DTC) INDEX .
  8. If no DTCs related to the concern are retrieved, GO to SYMPTOM CHART .
SMART JUNCTION BOX (SJB) DIAGNOSTIC TROUBLE CODE (DTC) INDEX

DTC Description Action
B1300 Power Door Lock Circuit Failure VERIFY the SJB fuse 9 (30A) is OK. If OK, INSTALL a new SJB. REFER to MULTIFUNCTION ELECTRONIC MODULES . TEST the system for normal operation.
B1396 Doors - Lock All Relay Circuit Coil Short to Battery CLEAR the DTCs. REPEAT the on-demand self-test. If DTC B1396 is retrieved again, INSTALL a new SJB. REFER to MULTIFUNCTION ELECTRONIC MODULES . TEST the system for normal operation.
B1397 Other Doors - Unlock All Relay Coil Circuit Short to Battery CLEAR the DTCs. REPEAT the on-demand self-test. If DTC 1397 is retrieved again, INSTALL a new SJB. REFER to MULTIFUNCTION ELECTRONIC MODULES . TEST the system for normal operation.
B1626 Keypad Illumination Circuit Short-to-Ground GO to PINPOINT TEST J .
B1982 Drivers Door - Unlock Relay Coil Circuit Failure VERIFY the SJB fuse 9 (30A) is OK. If OK, INSTALL a new SJB. REFER to MULTIFUNCTION ELECTRONIC MODULES . TEST the system for normal operation.
B2111 All Door Lock Input Short-to-Ground GO to PINPOINT TEST B .
B2250 All Doors - Unlock All Relay Coil Circuit Failure VERIFY the SJB fuse 9 (30A) is OK. If OK, INSTALL a new SJB. REFER to MULTIFUNCTION ELECTRONIC MODULES . TEST the system for normal operation.
B2425 Remote Keyless Entry Out of Synchronization GO to PINPOINT TEST E .
B2695 Keypad_A Switch Circuit Failure GO to PINPOINT TEST I .
B2696 Keypad_B Switch Circuit Failure GO to PINPOINT TEST I .
B2697 Keypad_C Switch Circuit Failure GO to PINPOINT TEST I .
All other DTCs - REFER to MULTIFUNCTION ELECTRONIC MODULES .