- Q1 CHECK CIRCUIT 261 (OG/BK) FOR AN OPEN
- Key in OFF position.
- Disconnect: Blower Motor Resistor C169.
- Key in ON position.
- Turn the function selector switch to the FLOOR position.
- Measure the voltage between blower motor resistor C1032, circuit 261 (OG/BK) and ground.
- Is the voltage greater than 10 volts?
- Yes : GO to Q2.
- No : REPAIR circuit 261 (OG/BK) for an open. TEST the system for normal operation.
- Q2 CHECK CIRCUIT 57 (BK) FOR AN OPEN
- Key in OFF position.
- Measure the resistance between blower motor resistor connector C1032, circuit 57 (BK) and ground.
- Is the resistance less than 5 ohms?
- Yes : GO to Q3.
- No : REPAIR circuit 57 (BK) for an open circuit. TEST the system for normal operation.
- Q3 CHECK MEDIUM/LOW BLOWER CIRCUIT 754 (LG/WH)
- Turn the blower motor switch to the medium/low position.
- Measure the resistance between blower motor resistor connector C1032, circuit 754 (LG/WH) and ground.
- Is the resistance less than 5 ohms?
- Yes : GO to Q4.
- No : GO to Q6.
- Q4 CHECK MEDIUM/HIGH BLOWER CIRCUIT 752 (YE/RD)
- Turn the blower motor switch to the medium/high position.
- Measure the resistance between blower motor resistor connector C1032, circuit 752 (YE/RD) and ground.
- Is the resistance less than 5 ohms?
- Yes : INSTALL a new blower motor resistor. REFER to CONTROL COMPONENTS . TEST the system for normal operation.
- No : GO to Q5.
- Q5 CHECK CIRCUIT 752 (YE/RD) FOR AN OPEN
- Disconnect: Blower Motor Switch C294c.
- Measure the resistance between blower motor resistor connector C1032, circuit 752 (YE/RD) and blower motor switch connector C294c, circuit 752 (YE/RD).
- Is the resistance less than 5 ohms?
- Yes : INSTALL a new blower motor switch. REFER to CONTROL COMPONENTS . TEST the system for normal operation.
- No : REPAIR circuit 752 (YE/RD) for an open. TEST the system for normal operation.
- Q6 CHECK CIRCUIT 754 (LG/WH) FOR AN OPEN
- Disconnect: Blower Motor Switch C294c.
- Measure the resistance between blower motor resistor connector C1032, circuit 754 (LG/WH) and blower motor switch connector C294c, circuit 754 (LG/WH).
- Is the resistance less than 5 ohms?
- Yes : INSTALL a new blower motor switch. REFER to CONTROL COMPONENTS . TEST the system for normal operation.
- No : REPAIR circuit 754 (LG/WH) for an open. TEST the system for normal operation.