Home >> Ford >> 2000 >> Taurus LX, 3.0 2, AX4N >> Repair and Diagnosis >> External Pages >> Different car >> Section 174 (HVAC Control System - General Information -- F250-F550 Super Duty) >> Diagnosis And Testing >> Climate Control System >> Pinpoint Tests >> Pinpoint Test P: No Operation In High Blower Setting - Manual Climate Control

Pinpoint Test P: No Operation In High Blower Setting - Manual Climate Control

WARNING: This page is about a different car, the 2005 Ford Pickup, 2005 Ford F550 Super Duty, 2005 Ford F450 Super Duty, and 2005 Ford Cab & Chassis. However, it is still accessible from the selected car via links, so may be relevant.
  1. P1 CHECK CIRCUIT 261 (OG/BK) FOR AN OPEN CIRCUIT 
    • Key in OFF position.
    • Disconnect: Blower Motor Switch C294c.
    • Key in ON position.
    • Turn the function selector switch to the FLOOR position.
    • Measure the voltage between blower motor switch connector C294c, circuit 261 (OG/BK) and ground.
      Fig 1: Checking Circuit 261 (OG/BK) For Open Circuit
      G03910197Courtesy of FORD MOTOR CO.
    • Is the voltage greater than 10 volts? 
    • Yes  : INSTALL a new blower motor switch. REFER to CONTROL COMPONENTS . TEST the system for normal operation.
    • No  : REPAIR circuit 261 (OG/BK) for an open circuit. TEST the system for normal operation.