LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2000 >> Taurus LX, 3.0 2, AX4N >> Repair and Diagnosis >> External Pages >> Different car >> Section 1723 (Wiper System & Washer System) >> Description And Operation >> Diagnosis And Testing >> Pinpoint Tests >> Pinpoint Test G: The Headlamps Do Not Illuminate When the Wipers are On >> Pinpoint Test G: The Headlamps Do Not Illuminate When The Wipers Are On

Pinpoint Test G: The Headlamps Do Not Illuminate When The Wipers Are On

WARNING: This page is about a different car, the 2011 Mercury Milan, 2011 Lincoln MKZ, and 2011 Ford Fusion. However, it is still accessible from the selected car via links, so may be relevant.
NOTE: Use the correct probe adapter(s) from the Flex Probe Kit when making measurements. Failure to use the correct probe adapter(s) may damage the connector.
  1. G1 CHECK WIPER ON SIGNAL FOR VOLTAGE 
    • Disconnect: Wiper/Washer Module C2157.
    • Ignition ON.
    • Measure the voltage between wiper/washer module C2157-2, circuit CRW01 (WH), harness side and ground.
      Fig 1: Measuring Voltage Between Wiper/Washer Module C2157-2, Circuit CRW01 (WH), Harness Side And Ground
      G06271574Courtesy of FORD MOTOR CO.
    • Is the voltage greater than 10 volts? 
    • Yes  : INSTALL a new wiper/washer module. REFER to WIPER/WASHER MODULE  in this service information. CLEAR the DTCs. REPEAT the self-test.
    • No  : GO to G2.
  2. G2 CHECK WIPER ON SIGNAL FOR AN OPEN OR SHORT TO GROUND 
    • Ignition OFF.
    • Disconnect: SJB C2280F.
    • Measure the resistance between SJB C2280F-8, circuit CRW01 (WH), harness side and wiper/washer module C2157-2, circuit CRW01 (WH); and between SJB C2280F-8, circuit CRW01 (WH), harness side and ground.
      Fig 2: Measuring Resistance Between SJB C2280F-8 And Wiper/Washer Module C2157-2 And Ground
      G06271575Courtesy of FORD MOTOR CO.
    • Is the resistance less than 5 ohms between the SJB and wiper/ washer module and greater than 10,000 ohms between the SJB and ground? 
    • Yes  : GO to G3.
    • No  : REPAIR the circuit. CLEAR the DTCs. REPEAT the self-test.
  3. G3 CHECK FOR CORRECT MODULE OPERATION 
    • Disconnect all the SJB connectors.
    • Check for:
      • corrosion.
      • pushed-out pins.
    • Connect all the SJB connectors and make sure they are seated correctly.
    • Operate the system and verify the concern is still present.
    • Is the concern still present? 
    • Yes  : INSTALL a new SJB. REFER to MULTIFUNCTION ELECTRONIC MODULES -- FUSION, MILAN & MKZ article. CLEAR the DTCs. REPEAT the self-test.
    • No  : The system is operating correctly at this time. Concern may have been caused by a loose or corroded connector. CLEAR the DTCs. REPEAT the self-test.