Pinpoint Test E: The Roof Opening Panel Does Not Open Or Close
WARNING: This page is about a different car, the 2007 Mercury Mariner and 2007 Ford Escape. However, it is still accessible from the selected car via links, so may be relevant.
- E1 THE ROOF OPENING PANEL DOES NOT OPEN OR CLOSE
- Key in OFF position.
- Disconnect: Roof Opening Panel Unit C919.
- Key in ON position.
- Measure the voltage between roof opening panel unit C919-1, circuit 1173 (BN/OG), harness side and ground.
- Is the voltage greater than 10 volts?
- YES : Go to E2
- NO : VERIFY the smart junction box (SJB) fuse 11 (15A) is OK. If OK, REPAIR the circuit. TEST the system for normal operation.
- E2 CHECK CIRCUIT 57 (BK) FOR AN OPEN
- Key in OFF position.
- Measure the resistance between roof opening panel unit C919-2, circuit 57 (BK), harness side and ground.
- Is the resistance less than 5 ohms?
- YES : Go to E3
- NO : REPAIR the circuit. TEST the system for normal operation.
- E3 CHECK CIRCUIT (DB) FOR POWER
- Key in OFF position.
- Disconnect: Roof Opening Panel Module Connector
- Key in ON position.
- Measure the voltage between the roof opening panel module connector, pin 6, circuit (DB), harness side and ground.
- Is the voltage greater than 10 volts?
- YES : Go to E4.
- NO : REPAIR the circuit. TEST the system for normal operation.
- E4 CHECK CIRCUIT (BK) FOR AN OPEN
- Key in OFF position.
- Measure the resistance between the roof opening panel module connector, pin 4, circuit (BK), harness side and ground.
- Is the resistance less than 5 ohms?
- YES : Go to E5.
- NO : REPAIR the circuit. TEST the system for normal operation.
- E5 CHECK POWER TO THE ROOF OPENING PANEL MOTOR - CIRCUIT (OG)
- Connect: Roof Opening Panel Module Connector
- Disconnect: Roof Opening Panel Motor Connector
- Key in ON position.
- While pressing the roof opening panel switch to the OPEN position, measure the voltage between the roof opening panel motor connector, pin 3, circuit (OG), harness side and ground.
- Is the voltage greater than 10 volts?
- E6 CHECK CIRCUIT (OG) FOR AN OPEN
- Key in OFF position.
- Disconnect: Roof Opening Panel Module Connector
- Measure the resistance between the roof opening panel motor connector, pin 3, circuit (OG), harness side and the roof opening panel module connector, pin 8, circuit (OG), harness side.
- Is the resistance less than 5 ohms?
- YES : Go to E7.
- NO : REPAIR the circuit. TEST the system for normal operation.
- E7 CHECK CIRCUIT (OG) FOR A SHORT TO GROUND
- Measure the resistance between the roof opening panel motor connector, pin 3, circuit (OG), harness side and ground.
- Is the resistance greater than 10,000 ohms?
- YES : Go to E11.
- NO : REPAIR the circuit. TEST the system for normal operation.
- E8 CHECK VOLTAGE TO THE ROOF OPENING PANEL MOTOR - CIRCUIT (RD)
- While pressing the roof opening panel switch to the CLOSED position, measure the voltage between the roof opening panel motor connector, pin 1, circuit (RD), harness side and ground.
- Is the voltage greater than 10 volts?
- YES : INSTALL a new roof opening panel motor. REFER to Roof Opening Panel Motor . TEST the system for normal operation.
- NO : Go to E9.
- E9 CHECK CIRCUIT (RD) FOR AN OPEN
- Key in OFF position.
- Disconnect: Roof Opening Panel Module Connector
- Measure the resistance between the roof opening panel module connector, pin 7, circuit (RD), harness side and the roof opening panel motor connector, pin 1, circuit (RD), harness side.
- Is the resistance less than 5 ohms?
- YES : Go to E10.
- NO : REPAIR the circuit. TEST the system for normal operation.
- E10 CHECK CIRCUIT (RD) FOR A SHORT TO GROUND
- Measure the resistance between the roof opening panel motor connector, pin 1, circuit (RD), harness side and ground.
- Is the resistance greater than 10,000 ohms?
- YES : Go to E11.
- NO : REPAIR the circuit. TEST the system for normal operation.
- E11 CHECK THE ROOF OPENING PANEL SWITCH
- Disconnect: Roof Opening Panel Switch Connector
- Measure the resistance between the roof opening panel switch pins 2 and 3, component side while pressing the roof opening panel switch to the CLOSED position; and between the roof opening panel switch pins 1 and 2, component side while pressing the roof opening panel switch to the OPEN position.
- Are the resistances less than 5 ohms?
- YES : Go to E12.
- NO : INSTALL a new roof opening panel switch. TEST the system for normal operation.
- E12 CHECK CIRCUIT (VT) FOR AN OPEN
- Disconnect: Roof Opening Panel Module Connector
- Connect: Roof Opening Panel Switch Connector
- Measure the resistance between the roof opening panel module connector, pin 3, circuit (VT), harness side and ground while pressing the roof opening panel switch to the CLOSED position.
- Is the resistance less than 5 ohms?
- YES : Go to E13.
- NO : REPAIR the circuit. TEST the system for normal operation
- E13 CHECK CIRCUIT (WH) FOR AN OPEN
- Measure the resistance between the roof opening panel module connector, pin 2, circuit (WH), harness side and ground while pressing the roof opening panel switch to the OPEN position.
- Is the resistance less than 5 ohms?
- YES : INSTALL a new roof opening panel module. REFER to Roof Opening Panel Module . TEST the system for normal operation.
- NO : REPAIR the circuit. TEST the system for normal operation.