Test B1: DTC C1095 - Abs Hydraulic Pump Motor Circuit Failure (Abs)
- Turn ignition on. Check ABS pump for continuous operation. If pump motor runs continuously, replace ABCM. If pump motor does not run continuously, go to next step.
- Turn ignition off. Disconnect ABCM connector (C385). Using DVOM, measure voltage between ABCM connector terminal No. 9 (Red wire) and ground. See WIRING DIAGRAMS . If voltage is greater than 10 volts, replace ABCM. If voltage is less than 10 volts, repair Red wire.