PID/Data Monitor & Record
- PID/Data Monitor and Record option allows technician using New Generation Star (NGS) tester to read the state of several Parameter IDs (PIDs) to aid in diagnosing the system. See PARAMETER IDENTIFICATION (PID) INDEX & VALUES table.
- Connect NGS tester to Data Link Connector (DLC), located under instrument panel. Turn ignition switch to RUN position. Select MODEL YEAR and VEHICLE. Select DIAGNOSTIC DATA LINK. Select RCM. Select DIAGNOSTIC TEST MODES. Select PID/DATA MONITOR AND RECORD. Record all PIDs that are to be retrieved and press START. PIDs are continuously updated on NGS display.
PARAMETER IDENTIFICATION (PID) INDEX & VALUES
| PID/Description | Range/Units |
|---|---|
| CCNT/number of continuous DTCs stored | 10 DTCs |
| VBAT/battery feed voltage at RCM | 9-16 volts |
| D-ABAGR/driver-side air bag module resistance | 1.7-4.1 ohms |
| P-ABAGR/passenger-side air bag module resistance | 1.7-3.2 ohms |
| BRACKET/bracket ground resistance | Less than 100 ohms |
| VID No 1/program vehicle ID pin 10 | Ignition |
| VID No 2/program vehicle ID pin 13 | Ignition |
| VID No 3/program vehicle ID pin 14 | No connection |