Pinpoint Test G: The Blower Motor Is Inoperative
WARNING: This page is about a different car, the 2005 Ford RV Cutaway, 2005 Ford Econoline, 2005 Ford E450 Super Duty, and 2005 Ford Cutaway. However, it is still accessible from the selected car via links, so may be relevant.
- G1 CHECK BLOWER MOTOR GROUND
- Disconnect: Blower Motor C1227.
- Turn the blower motor switch to the HIGH position.
- Measure the resistance between A/C blower motor C1227-1, circuit 261 (OG/BK) and ground.
- Is the resistance less than 5 ohms?
- Yes : GO to G4.
- No : GO to G2.
- G2 CHECK CIRCUIT 261 (OG/BK) FOR AN OPEN
- Disconnect: Blower Motor Switch C294b.
- Measure the resistance between blower motor switch C294b-1, circuit 261 (OG/BK) and blower motor C1227-1, circuit 261 (OG/BK).
- Is the resistance less than 5 ohms?
- Yes : GO to G3.
- No : REPAIR circuit 261 (OG/BK) for an open. TEST the system for normal operation.
- G3 CHECK CIRCUIT 57 (BK) FOR AN OPEN
- Measure the resistance between blower motor switch C294b-2, circuit 57 (BK) and ground.
- Is the resistance less than 5 ohms?
- Yes : INSTALL a new blower motor switch. REFER to CONTROL COMPONENTS . TEST the system for normal operation.
- No : REPAIR circuit 57 (BK) for an open. TEST the system for normal operation.
- G4 CHECK A/C BLOWER MOTOR CIRCUIT 515 (OG/RD) FOR VOLTAGE
- Key in ON position.
- Measure the voltage between A/C blower motor C1227-2, circuit 515 (OG/RD) and ground.
- Is the voltage greater than 10 volts?
- Yes : INSTALL a new blower motor. REFER to HEATING & VENTILATION . TEST the system for normal operation.
- No : GO to G5.
- G5 CHECK CIRCUIT 515 (OG/RD) FOR AN OPEN
- Key in OFF position.
- Disconnect: Blower Motor Relay.
- Measure the resistance between blower motor relay connector pin 87, circuit 515 (OG/RD) and blower motor C1227-2, circuit 515 (OG/RD).
- Is the resistance less than 5 ohms?
- Yes : GO to G6.
- No : REPAIR circuit 515 (OG/RD) for an open. TEST the system for normal operation.
- G6 CHECK THE BLOWER MOTOR RELAY
- Connect: Blower Motor C1227.
- Key in ON position.
- Connect a fused jumper lead between the blower motor relay socket pin 30, circuit 364 (BK/LG) and pin 87, circuit 515 (OG/RD).
- Does the blower motor operate?
- Yes : GO to G7.
- No : VERIFY the battery junction box (BJB) fuse 17 (50A) is OK. If OK, REPAIR circuit 364 (BK/LG) for an open. TEST the system for normal operation.
- G7 CHECK CIRCUIT 57 (BK) FOR AN OPEN
- Key in OFF position.
- Measure the resistance between blower motor relay socket pin 86, circuit 57 (BK) and ground.
- Is the resistance less than 5 ohms?
- Yes : GO to G8.
- No : REPAIR circuit 57 (BK) for an open. TEST the system for normal operation.
- G8 CHECK THE BLOWER MOTOR RELAY
- Key in ON position.
- Measure the voltage between blower motor relay socket pin 85, circuit 753 (YE/RD) and socket pin 86, circuit 57 (BK).
- Is the voltage greater than 10 volts?
- Yes : INSTALL a new blower motor relay. TEST the system for normal operation.
- No : GO to G9.
- G9 CHECK CIRCUIT 753 (YE/RD) FOR AN OPEN
- Key in OFF position.
- Measure the resistance between blower motor relay connector pin 85, circuit 753 (YE/RD) and function selector switch C294a-3, circuit 753 (YE/RD).
- Is the resistance less than 5 ohms?
- Yes : GO to G10.
- No : REPAIR circuit 753 (YE/RD) for an open. TEST the system for normal operation.
- G10 CHECK CIRCUIT 489 (PK/BK) FOR VOLTAGE
- Key in ON position.
- Measure the voltage between blower motor switch C294a-4, circuit 489 (PK/BK) and ground.
- Is the voltage greater than 10 volts?
- Yes : INSTALL a new function selector switch. REFER to CONTROL COMPONENTS . TEST the system for normal operation.
- No : VERIFY the central junction box (CJB) fuse 13 (15A) is OK. REPAIR circuit 489 (PK/BK) for an open. TEST the system for normal operation.