LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2000 >> Contour SE, 2.5 L, Standard >> Repair and Diagnosis >> External Pages >> Different car >> Section 751 (Engine Controls - Diagnostic Methods - CNG, Flex-Fuel & Gasoline) >> Drive Cycles >> Description of OBD II Drive Cycle

Description of OBD II Drive Cycle

WARNING: This page does not describe the selected car, but rather 30 other vehicles, including the 2004 Mercury Sable, 2004 Mercury Mountaineer, 2004 Mercury Monterey, 2004 Mercury Marauder, and 2004 Mercury Grand Marquis. However, it is still accessible from the selected car via links, so may be relevant.

The following procedure is designed to execute and complete the OBDII monitors and to clear the Ford P1000, I/M readiness code. To complete a specific monitor for repair verification, follow steps 1 through 4, then continue with the step described by the appropriate monitor found under the "OBDII Monitor Exercised" column. When the ambient air temperature is outside 4.4 to 37.8°C (40 to 100 °F), or the altitude is above 2438 meters (8000 feet), the EVAP monitor will not run. If the P1000 code must be cleared in these conditions, the PCM must detect them once (twice on some applications) before the EVAP monitor can be "bypassed" and the P1000 cleared. The EVAP "bypassing" procedure is described in the following drive cycle.

The OBDII Drive Cycle will be performed using a scan tool. Consult the instruction manual for each described function.

NOTE: A detailed description for clearing the DTCs is found in this article. Refer to CLEAR THE CONTINUOUS DIAGNOSTIC TROUBLE CODES (DTCS) AND RESET THE EMISSION MONITORS INFORMATION IN THE POWERTRAIN CONTROL MODULE (PCM) .