Solenoid - Stuck Closed or Does Not Operate
WARNING: This page is about a different car, the 2003 Ford Econoline and 2003 Ford E450 Super Duty. However, it is still accessible from the selected car via links, so may be relevant.
- Turn in the manual lockdown valve jackscrew on the fuel tank solenoid valve(s).
- Perform the fuel line venting procedure. For additional information, refer to FUEL LINE EVACUATION .
- Disconnect the fuel fill line from the fuel fill valve.
- Connect the Fuel Venting Kit and Adapter to the fuel fill line.
- Connect the Grounding Cable to the back side of the fuel fill valve at the fuel line connection.
- Connect the Grounding Cable to the ground rod.
- Connect the Fuel Filler Neck Venting Kit to the Venting Hose Assembly and Adapter.
- Connect the Fuel Venting Kit to the Fuel Filler Neck Venting Kit.
- Connect the Venting Hose Assembly to the vent stack.
- Remove the manual lockdown valve from the fuel tank solenoid valve of the fuel tank to be vented.
- Install the override tool into the fuel tank solenoid valve of the tank to be vented.
- Slowly turn in the override tool jackscrew until fuel flows. Observe the gauge pressure of the Fuel Filler Neck Venting Kit. The pressure reading should be at tank pressure.
- Slowly open the bleed valve on the venting kit and allow the contents of the fuel tank to vent to the atmosphere. Venting can take in excess of one hour.
- Vent the fuel tank until the fuel flow stops.
- Remove the override tool from the fuel tank solenoid valve.
- Install the fuel tank solenoid manual lockdown valve.
- Turn in the manual lockdown valve jackscrew on the fuel tank solenoid valve.
- Repeat the procedure until all affected tanks are vented.
- Install the fuel fill line onto the fuel fill valve.
NOTE:
On vehicles equipped with an extended range fuel tank, the jackscrew can be reached through an access hole in the vapor retaining cover.
NOTE:
Solenoid diagnostics must be completed on all tank solenoid valves prior to venting.
NOTE:
All fuel tank solenoid valves must be in the locked down position.
WARNING:
Make sure that the jackscrew in the Manual Override Tool is retracted fully (counterclockwise) prior to installation into the fuel tank solenoid valve. Installation of the override tool in the venting position will cause natural gas to be immediately released.
CAUTION:
Once the fuel tank solenoid valve has been opened using the override tool, a new fuel tank solenoid valve must be installed.