LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2000 >> Contour SE, 2.5 L, Standard >> Repair and Diagnosis >> External Pages >> Different car >> Section 64 (Starting System - Excursion & F250-F550 Super Duty) >> Bench Testing >> Starter No-Load Test

Starter No-Load Test

WARNING: This page is about a different car, the 2002 Ford Pickup, 2002 Ford F550 Super Duty, 2002 Ford F450 Super Duty, 2002 Ford Excursion, and 2002 Ford Cab & Chassis. However, it is still accessible from the selected car via links, so may be relevant.
  1. Remove starter motor. See STARTER MOTOR  under REMOVAL & INSTALLATION. Place starter motor securely in a vise. Connect remote starter switch between positive battery terminal and starter motor "S" terminal. Connect starter motor "B" terminal to positive battery post. See Figure. Connect Alternator, Regulator, Battery and Starter Tester (ARBST), or equivalent, according to tool manufacturers instructions.
  2. Ensure starter motor is grounded. Engage remote starter switch. Starter should eject starter drive and turn smoothly and quietly. DVOM should indicate 11 volts or more. Amperage draw should no more than 170 amps. See STARTER MOTOR SPECIFICATIONS . If voltage is lower or current is higher than specification, or unusual noise is present, install new starter motor.