Pinpoint Test AJ: A Single Power Window Is Inoperative - RH
- AJ1 CHECK THE OPERATION FROM THE LH WINDOW CONTROL SWITCH
- Key in ON position.
- Operate the RH window from the LH window control switch.
- Does the RH window operate from the LH window control switch?
Yes
GO to AJ12 .
No
GO to AJ2.
- AJ2 CHECK CIRCUIT 1506 (RD/WH) FOR GROUND
- Key in OFF position.
- Disconnect: RH Window Motor C623.
- Measure the resistance between the RH window motor C623-1, circuit 1506 (RD/WH), harness side and ground.
- Is the resistance less than 5 ohms?
Yes
GO to AJ6.
No
GO to AJ3.
- AJ3 CHECK CIRCUIT 313 (WH/YE) FOR GROUND
- Key in OFF position.
- Disconnect: RH Window Control Switch C624.
- Measure the resistance between the RH window control switch C624-6, circuit 313 (WH/YE), harness side and ground.
- Is the resistance less than 5 ohms?
Yes
GO to AJ5
No
GO to AJ4.
- AJ4 CHECK CIRCUIT 313 (WH/YE) FOR AN OPEN
- Disconnect: LH Window Control Switch C508a.
- Measure the resistance between the LH window control switch C508a-3, circuit 313 (WH/YE), harness side and the RH window control switch C624-6, circuit 313 (WH/YE), harness side.
- Is the resistance less than 5 ohms?
Yes
GO to AJ13
No
REPAIR the circuit. TEST the system for normal operation.
- AJ5 CHECK CIRCUIT 1506 (RD/WH) FOR AN OPEN
- Measure the resistance between the RH window control switch C624-5, circuit 1506 (RD/WH), harness side and the RH window motor C623-1, circuit 1506 (RD/WH), harness side.
- Is the resistance less than 5 ohms?
Yes
INSTALL a new RH window control switch. TEST the system for normal operation.
No
REPAIR the circuit. TEST the system for normal operation.
- AJ6 CHECK CIRCUIT 1506 (RD/WH) FOR A SHORT TO GROUND
- Disconnect: LH Window Control Switch C508a.
- Measure the resistance between the RH window motor C623-1, circuit 1506 (RD/WH), harness side and ground.
- Is the resistance greater than 10,000 ohms?
Yes
GO to AJ7
No
REPAIR the circuit. TEST the system for normal operation.
- AJ7 CHECK CIRCUIT 1505 (YE/RD) FOR GROUND
- Connect: LH Window Control Switch C508a.
- Measure the resistance between the RH window motor C623-2, circuit 1505 (YE/RD), harness side and ground.
- Is the resistance less than 5 ohms?
Yes
GO to AJ11
No
GO to AJ8.
- AJ8 CHECK CIRCUIT 314 (TN/LB) FOR GROUND
- Disconnect: RH Window Control Switch C624.
- Measure the resistance between the RH window control switch C624-1, circuit 314 (TN/LB), harness side and ground.
- Is the resistance less than 5 ohms?
Yes
GO to AJ10
No
GO to AJ9.
- AJ9 CHECK CIRCUIT 314 (TN/LB) FOR AN OPEN
- Disconnect: LH Window Control Switch C508a.
- Measure the resistance between the LH window control switch C508a-2, circuit 314 (TN/LB), harness side and RH window control switch C624-1, circuit 314 (TN/LB), harness side.
- Is the resistance greater than 10,000 ohms?
Yes
GO to AJ13
No
REPAIR the circuit. TEST the system for normal operation.
- AJ10 CHECK CIRCUIT 1505 (YE/RD) FOR AN OPEN
- Measure the resistance between the RH window control switch C624-2, circuit 1505 (YE/RD), harness side and the RH window motor C623-2, circuit 1505 (YE/RD), harness side.
- Is the resistance less than 5 ohms?
Yes
INSTALL a new RH window control switch. TEST the system for normal operation.
No
REPAIR the circuit. TEST the system for normal operation.
- AJ11 CHECK CIRCUIT 1505 (YE/RD) FOR A SHORT TO GROUND
- Disconnect: LH Window Control Switch C508a.
- Measure the resistance between the RH window motor C623-2, circuit 1505 (YE/RD), harness side and ground.
- Is the resistance greater than 10,000 ohms?
Yes
INSTALL a new RH window motor. Refer to DOOR WINDOW GLASS - FRONT . TEST the system for normal operation.
No
REPAIR the circuit. TEST the system for normal operation.
- AJ12 CHECK THE POWER SUPPLY TO THE RH WINDOW CONTROL SWITCH
- Key in OFF position.
- Disconnect: RH Window Control Switch C624.
- Key in ON position.
- Measure the voltage between the RH window control switch C624-3, circuit 170 (RD/LB), harness side and ground.
- Is the voltage greater than 10 volts?
Yes
INSTALL a new RH window control switch. TEST the system for normal operation.
No
REPAIR the circuit. TEST the system for normal operation.
- AJ13 CHECK CIRCUIT 1205 (BK) FOR GROUND
- Disconnect: LH Window Control Switch C508a.
- Measure the resistance between the LH window control switch C508a-1, circuit 1205 (BK), harness side and ground.
- Is the resistance less than 5 ohms?
Yes
INSTALL a new LH window control switch. TEST the system for normal operation.
No
REPAIR the circuit. TEST the system for normal operation.