Drive Cycle Preparation

WARNING: This page is about a different car, the 2004 Mercury Monterey and 2004 Ford Freestar. However, it is still accessible from the selected car via links, so may be relevant.
NOTE: For best results, follow each of the following steps as accurately as possible.
    NOTE: This step bypasses the engine soak timer and resets OBD II monitor status.
  1. Install the scan tool. Turn the key ON with the engine OFF. Cycle the key off, then on. Select the appropriate vehicle and engine qualifier. Clear all diagnostic trouble codes (DTCs) and carry out a PCM reset.
  2. Begin to monitor the following PIDs: ECT, EVAPDC, FLI (if available) and TP MODE. Press Diagnostic Data Link, PCM, PID/Data monitor and record, press trigger to select each PID, then start.
  3. Start the engine without returning the key to the OFF position.