LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2000 >> Contour SE, 2.5 L, Standard >> Repair and Diagnosis >> External Pages >> Different car >> Section 44 (Cooling System Specifications & Drive Belt Routing) >> Cooling System Specifications >> Cooling System Specifications (ECONOLINE)

Cooling System Specifications (ECONOLINE)

WARNING: This page does not describe the selected car, but rather 20 other vehicles, including the 2002 Mercury Villager, 2002 Mercury Mountaineer, 2002 Lincoln Navigator, 2002 Lincoln Blackwood, and 2002 Ford Windstar. However, it is still accessible from the selected car via links, so may be relevant.
COOLING SYSTEM SPECIFICATIONS (ECONOLINE)

Application Specification
Coolant Capacity
4.2L 23.3 Qts. (22.0L)
4.6L 25.0 Qts. (23.7L)
5.4L 29.0 Qts. (27.4L)
6.8L (1)
7.3L Diesel 30.0 Qts. (28.4L)
Cooling System Test Pressure 18 psi (1.27 kg/cm2 )
Pressure Relief Cap Opening Pressure 13 psi (.91 kg/cm2 )
Thermostat Opens
4.2L, 4.6L & 5.4L
Starts 188-195°F (87-91°C)
Fully Open 212°F (100°C)
6.8L
Starts 181-187°F (83-86°C)
Fully Open 210°F (99°C)
7.3L Diesel (1)
(1) Information not provided by manufacturer.