LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2000 >> Contour SE, 2.5 L, Standard >> Repair and Diagnosis >> External Pages >> Different car >> Section 40 (Manual HVAC Systems - F150) >> Removal & Installation >> Orifice Tube >> Removal & Installation

Removal & Installation

WARNING: This page is about a different car, the 2002 Ford Pickup. However, it is still accessible from the selected car via links, so may be relevant.
  1. Disconnect negative battery cable. Discharge A/C system, using approved refrigerant recovery/recycling equipment. See RECOVERY, EVACUATION & RECHARGING in GENERAL SERVICING PROCEDURES article in GENERAL SERVICING. Disconnect condenser-to-evaporator refrigerant line at evaporator. Inspect orifice tube condition. See Fig 1.
  2. If orifice tube is broken, using Orifice Tube Remover (T83L-19990-B), screw end of remover into broken orifice tube. See Fig 2. Hold "T" handle while rotating orifice tube remover body to remove broken orifice tube. See Fig 4.
  3. If orifice tube is not broken, using Orifice Tube Remover (T83L-19990-A), engage tube inside refrigerant line. See Fig 3. Hold "T" handle while rotating orifice tube remover body to remove fixed orifice tube. See Fig 4.
  4. To install, reverse removal procedure. Coat NEW "O" rings with clean refrigerant oil. See Fig 5. Add 2 ounces (60 ml) of clean PAG Refrigerant Compressor Oil or equivalent to accumulator-drier inlet tube. Evacuate, charge, and leak test A/C system. See RECOVERY, EVACUATION & RECHARGING in GENERAL SERVICING PROCEDURES article in GENERAL SERVICING.
Fig 1: Inspecting Orifice Tube
G00168145Courtesy of FORD MOTOR CO.
Fig 2: Removing Broken Orifice Tube
G00168149Courtesy of FORD MOTOR CO.
Fig 3: Removing Non-Broken Orifice Tube
G00168147Courtesy of FORD MOTOR CO.
Fig 4: Using Special Tool
G00168148Courtesy of FORD MOTOR CO.
Fig 5: Locating Orifice Tube "O" Rings
G00168146Courtesy of FORD MOTOR CO.