LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2000 >> Contour SE, 2.5 L, Standard >> Repair and Diagnosis >> External Pages >> Different car >> Section 375 (Engine System - General Information) >> Diagnosis And Testing >> Engine >> Intake Manifold Vacuum Test

Intake Manifold Vacuum Test

WARNING: This page is about a different car, the 2002 Ford Econoline, 2002 Ford E550 Super Duty, 2002 Ford E450 Super Duty, and 2002 Ford Cutaway. However, it is still accessible from the selected car via links, so may be relevant.

Bring the engine to normal operating temperature. Connect the Vacuum/Pressure Tester to the intake manifold. Run the engine at the specified idle speed.

The vacuum gauge should read between 51-74 kPa (15-22 in-Hg) depending upon the engine condition and the altitude at which the test is performed. Subtract 4.0193 kPa (1 in-Hg) from the specified reading for every 304.8 m (1,000 feet) of elevation above sea level.

The reading should be steady. If necessary, adjust the gauge damper control (where used) if the needle is fluttering rapidly.

Adjust the damper until the needle moves easily without excessive flutter.