LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2000 >> Contour SE, 2.5 L, Standard >> Repair and Diagnosis >> External Pages >> Different car >> Section 303 (Overhaul - Automatic Transmission) >> Disassembly & Assembly Of Subassemblies >> Torque Converter Leak Check >> Special Tool(s)

Special Tool(s)

WARNING: This page is about a different car, the 2002 Ford Ranger. However, it is still accessible from the selected car via links, so may be relevant.
Fig 1: Identifying Special Tool(s)
G02152977Courtesy of FORD MOTOR CO.
  1. Clean the outside surface of the torque converter.
  2. Install the special tool into converter hub.
    Fig 2: Installing Special Tool Into Converter Hub
    G02152978Courtesy of FORD MOTOR CO.
  3. WARNING: Always follow correct safety procedures while using the press. Failure to follow these instructions may result in personal injury.
    Fig 3: Installing Torque Converter With Special Tool Into Arbor Press
    G02152979Courtesy of FORD MOTOR CO.
  4. Install the torque converter with the special tool into the Arbor press.

    Secure the press. Apply enough force from the press to seal the special tool into the torque converter.

  5. NOTE: Use clean, dry shop air.
    Fig 4: Applying Air Pressure To Valve On Leak Check Tool
    G02152980Courtesy of FORD MOTOR CO.
  6. Apply air pressure to valve on leak check tool.
  7. With air pressure applied to the special tool valve, inspect for leaks at the converter hub, the seams and the studs. A soap bubble solution can be applied around those areas to aid in the diagnosis. If any leaks are present, install a new or remanufactured torque converter.
    Fig 5: Inspecting For Leaks At Converter Hub
    G02152981Courtesy of FORD MOTOR CO.
  8. Remove the air hose. Release the pressure, and then slowly release the press. Remove the converter. Remove the special tool.
    Fig 6: Releasing Pressure & Then Slowly Releasing Press
    G02152982Courtesy of FORD MOTOR CO.