LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2000 >> Contour SE, 2.5 L, Standard >> Repair and Diagnosis >> External Pages >> Different car >> Section 2778 (Engine Controls - Reference Values - Navigator Through Town Car - CNG, Flex-Fuel & Gasoline) >> Taurus/Sable 3.0L 4V

Taurus/Sable 3.0L 4V

WARNING: This page does not describe the selected car, but rather 30 other vehicles, including the 2004 Mercury Sable, 2004 Mercury Mountaineer, 2004 Mercury Monterey, 2004 Mercury Marauder, and 2004 Mercury Grand Marquis. However, it is still accessible from the selected car via links, so may be relevant.
Fig 1: Identifying 104 Pin PCM Connector - 3.0L 4V Taurus/Sable
G03626777Courtesy of FORD MOTOR CO.
SENSORS/INPUT - 3.0L 4V TAURUS/SABLE

Sensors/Inputs PCM Pin/PID only Measured/PID Values Units Measured/PID
KOEO Hot Idle 30 MPH 55 MPH
TR1 3 10.7  10.7  DCV
TSS 6 43/700  85-105/1480-1570  110-125/1690-2000  Hz/RPM
FEPS 13 .5-.6  .5-.6  .5-.6  .5-.6  DCV
PATSIN 17 (T)  (T)  (T)  (T)  (T)
CKP (+) 21 390-520  850-1120  1140-1220  Hz
TCS 29 .1/OFF  VBAT/ON (G)  .1/OFF  .1/OFF  DCV/OFF-ON
PSP V/PSP 31 .1/LOW  VBAT/HIGH (I)  .1/LOW  .1/LOW  DCV/LOW-HIGH
02S12 35 .1  (D)  (D)  (D)  DCV
TFT 37 .5-2/210-110  .5-2/210-110  .5-2/210-110  .5-2/210-110  DCV/DEG
ECT 38 .4-1/200-160  .4-1/200-160  .4-1/200-160  .4-1/200-160  DCV/DEG
IAT 39 1.7-3.5/120-50 (K)  1.7-3.5/120-50 (K)  1.7-3.5/120-50 (K)  1.7-3.5/120-50 (K)  DCV/DEG
FPM 40 0-7/85-115  0-7/85-115  0-7/85-115  0-7/85-115  DCV/%
ACCS 41 .1/OFF  VBAT/ON (A)  .1/OFF  .1/OFF  DCV/OFF-ON
GFS (ALTMON) 45 130/30  130/27  130/23  Hz/%
TR2 49 10.7  10.7  DCV
TR4 50 10.7  10.7  DCV
KS1 57 DCV
02S11 60 switching (C)  switching (C)  switching (C)  DCV
02S22 61 (D)  (D)  (D)  DCV
FTP V/FTP 62 2.6/.41  2.6/.41  2.6/.41  2.6/.41  DCV/IN-H2O
FRP V/FRP 63 3.15/46  2.74/39  2.88/41  2.86/40  DCV/OFF-ON
TR3 V/TR3 64 4.4/PARK  4.4/PARK  2.1/OD  2.1/OD  DCV/MODE
DPFEGR 65 .25-1.3  .25-1.3  .25-4.65  .25-4.65  DCV
ACET 66 1.9-4.0  1.9-4.0  1.9-4.0  1.9-4.0  DCV
OSS 84 300/1650  506/2600  Hz/RPM
CID 85 5-7  10-13  14-17  Hz
ACP V/ACP 86 VBAT/OPEN  VBAT/OPEN  VBAT/OPEN  VBAT/OPEN  DCV/OPEN-CLOSED
O2S21 87 switching (C)  switching (C)  switching (C)  DCV
MAF V 88 .5-.7  .7-1.5  1.3-2  DCV
TP V 89 .53-1.27  .53-1.27  .8-1.1  1-1.5  DCV
BPP 92 .1/OFF  VBAT/ON (E)  .1/OFF  .1/OFF  DCV/OFF-ON
CPP/PNP PID ON  ON  OFF  OFF  OFF-ON
GEAR PID GEAR
LOAD PID (L)  15-20  20-35  15-35  %
MISF PID OFF  OFF  OFF  OFF  OFF-ON
OCTADJS PID NO RETARD  NO RETARD  NO RETARD  NO RETARD  NO RETARD/RETARD
RPM PID 674-734  1350-1650  1800-2060  RPM
VSS PID 30  55  MPH
ACTUATORS/OUTPUTS - 3.0L 4V TAURUS/SABLE

Actuators/Outputs PCM Pin/PID only Measured/PID Values Units Measured/PID
KOEO Hot Idle 30 MPH 55 MPH
SS2 1 .1/ON  .1/ON  VBAT/OFF  .1/ON  DCV/OFF-ON
CDD (CYL5) 2 VBAT  VBAT  VBAT  VBAT  DCV
PATSOUT 18 (T)  (T)  (T)  (T)  (T)
GENFDC (ALTCOM) 20 Hz/%
CDA (CYL1) 26 VBAT  VBAT  VBAT  VBAT  DCV
SS1 27 VBAT/OFF  VBAT/OFF  .1/ON  .1/ON  DCV/OFF-ON
LFC (FC1) 28 VBAT/OFF  .1/ON (B)  VBAT/OFF  VBAT/OFF  DCV/OFF-ON
PATSIL 30 (T)  (T)  (T)  (T)  (T)
MFC (FC2) 42 VBAT/OFF  .1/ON (B)  VBAT/OFF  VBAT/OFF  DCV/OFF-ON
PATSTRT 44 (T)  (T)  (T)  (T)  (T)
HFC (FC3) 46 VBAT/OFF  .1/ON (B)  VBAT/OFF  VBAT/OFF  DCV/OFF-ON
EGRVR 47 VBAT/0  VBAT/0  (V)  (V)  DCV/%
CTO 48 33-45  75-85  92-120  Hz
CDB (CYL4) 52 VBAT  VBAT  VBAT  VBAT  DCV
SS3 53 VBAT/OFF  VBAT/OFF  .1/ON  .1/ON  DCV/OFF-ON
TCC 54 VBAT/0  VBAT/0  .2/100  .2/100  DCV/%
EVMV 56 500-900 (F)  500-900 (F)  mA
EVAPCV 67 VBAT/0  VBAT/0  VBAT/0 (S)  VBAT/0 (S)  DCV/%
VSO 68 65  125  Hz/RPM
WAC (ACCR) 69 VBAT/OFF  .1/ON (A)  VBAT/OFF  VBAT/OFF  DCV/OFF-ON
INJ5 73 2.2-2.7  2.3-5.5  2-7  mS
INJ3 74 2.2-2.7  2.3-5.5  2-7  mS
INJ1 75 2.2-2.7  2.3-5.5  2-7  mS
CDC (CYL2) 78 VBAT  VBAT  VBAT  VBAT  DCV
CDE (CYL3) 79 VBAT  VBAT  VBAT  VBAT  DCV
FP 80 3.6/75  .1/100  .1/100  .1/100  DCV/%
EPC 81 7.5/15  9/15  8.9-10.1/16-25  9.2/27  DCV/%
CDF (CYL6) 82 VBAT  VBAT  VBAT  VBAT  DCV
IAC 83 VBAT/0  9.8-11.2/24-52  7.5-10/24-52 (L)  7.2-8.0/50-59 (L)  DCV/%
HTR11 93 VBAT/OFF  switching  switching  switching  DCV/OFF-ON
HTR21 94 VBAT/OFF  switching  switching  switching  DCV/OFF-ON
HTR12 95 VBAT/OFF  .2/ON  .2/ON  .2/ON  DCV/OFF-ON
HTR22 96 VBAT/OFF  .2/ON  .2/ON  .2/ON  DCV/OFF-ON
INJ6 99 2.2-2.7  2.3-5.5  2-7  mS
INJ4 100 2.2-2.7  2.3-5.5  2-7  mS
INJ2 101 2.2-2.7  2.3-5.5  2-7  mS
LONGFT1 PID (-)20-(+)20  (-)20-(+)20  (-)20-(+)20  (-)20-(+)20  %
LONGFT2 PID (-)20-(+)20  (-)20-(+)20  (-)20-(+)20  (-)20-(+)20  %
SHRTFT1 PID (L)  (-)10-(+)10  (-)10-(+)10  (-)10-(+)10  %
SHRTFT2 PID (L)  (-)10-(+)10  (-)10-(+)10  (-)10-(+)10  %
SPARKADV PID 12-27  25-42  20-40  DEG
OTHERS - 3.0L 4V TAURUS/SABLE

Other PCM Pin/PID only Measured/PID Values Units Measured/PID
KOEO Hot Idle 30 MPH 55 MPH
KAPWR 55 VBAT  VBAT  VBAT  VBAT  DCV
VPWR 71,97 VBAT  VBAT  VBAT  VBAT  DCV
VREF 90 DCV
GENERIC OBD II PID VALUES - 3.0L 4V TAURUS/SABLE

NOTE: All generic OBD II readings under no load (PARK or NEUTRAL).
PID Hot Idle 2500 RPM Units
LONGFT1 (-)20-(+)20  (-)20-(+)20  %
LONGFT2 (-)20-(+)20  (-)20-(+)20  %
LOAD 30-34  30-40  %
MAF 3.5-4  12-14  G/S
SHRTFT1 (-)10-(+)10  (-)10-(+)10  %
SHRTFT2 (-)10-(+)10  (-)10-(+)10  %
SHRTFT11 (-)10-(+)10  (-)10-(+)10  %
SHRTFT12 95-100  95-100  %
SHRTFT21 (-)10-(+)10  (-)10-(+)10  %
SHRTFT22 95-100  95-100  %
SPARKADV 12-17  35-40  DEG