Ranger 3.0L (A/T)

WARNING: This page does not describe the selected car, but rather 30 other vehicles, including the 2004 Mercury Sable, 2004 Mercury Mountaineer, 2004 Mercury Monterey, 2004 Mercury Marauder, and 2004 Mercury Grand Marquis. However, it is still accessible from the selected car via links, so may be relevant.
Fig 1: Identifying 104 Pin PCM Connector - 3.0L Ranger (A/T)
G03626777Courtesy of FORD MOTOR CO.
SENSORS/INPUT - 3.0L RANGER (A/T)

Sensors/Inputs PCM Pin/PID only Measured/PID Values Units Measured/PID
KOEO Hot Idle 30 MPH 55 MPH
TR1 3 11.5  11.5  DCV
TSS 6 115-120/870-920  140-190/1000-1400  268-275/2010-2080  Hz/MPH
FLI V/FLI (H) 12 1.7/50  1.7/50  1.7/50  1.7/50  DCV/%
FEPS 13 .5-.6  .5-.6  .5-.6  .5-.6  DCV
4X4L (M) 14 VBAT/OFF  VBAT/OFF  VBAT/OFF  VBAT/OFF  DCV/OFF-ON
PATSIN 17 VBAT  VBAT  VBAT  VBAT  DCV
CKP (+) 21 460-480  800-855  1180-1230  Hz
TCS 29 .1/OFF  VBAT/ON (G)  .1/OFF  .1/OFF  DCV/OFF-ON
O2S12 35 .1  (D)  (D)  (D)  DCV
TFT 37 .5-2/210-110  .5-2/210-110  .5-2/210-110  .5-2/210-110  DCV/DEG
ECT 38 .4-1/200-160  .4-1/200-160  .4-1/200-160  .4-1/200-160  DCV/DEG
IAT 39 1.7-3.5/120-50 (K)  1.7-3.5/120-50 (K)  1.7-3.5/120-50 (K)  1.7-3.5/120-50 (K)  DCV/DEG
FPM 40 .1/OFF  VBAT/ON  VBAT/ON  VBAT/ON  DCV/OFF-ON
ACCS 41 .1/OFF  VBAT/ON (A)  .1/OFF  .1/OFF  DCV/OFF-ON
TR2 49 11.5  11.5  DCV
TR4 50 11.5  11.5  DCV
KS1 57 DCV
ISS 59 623  1480  1980  Hz
O2S11 60 switching (C)  switching (C)  switching (C)  DCV
FTP V/FTP 62 2.6/0  2.6/0  2.6/0  2.6/0  DCV/IN-H2O
TRV/TR 64 0/PARK  0/PARK  1.7/OD  1.7/OD  DCV/MODE
DPFEGR 65 .25-1.3  .25-1.3  .25-4.65  .25-4.65  DCV
OSS 84 290/1435  530/2640  Hz/RPM
CID 85 6-8  13-15  17-19  Hz
ACP V/ACP 86 .1/CLOSED  .1/CLOSED  .1/CLOSED  .1/CLOSED  DCV/OPEN-CLOSED
O2S21 87 switching (C)  switching (C)  switching (C)  DCV
MAF V 88 .8-1.1  1.4-1.7  2-2.5  DCV
TP V 89 .53-1.27  .53-1.27  1-1.2  1.2-1.7  DCV
BPP 92 .1/OFF  VBAT/ON (E)  .1/OFF  .1/OFF  DCV/OFF-ON
CPP/PNP PID ON  ON  OFF  OFF  OFF-ON
GEAR PID GEAR
LOAD PID (L)  17-21  23-27  35-40  %
MISF PID OFF  OFF  OFF  OFF  OFF-ON
OCTADJS PID NO RETARD  NO RETARD  NO RETARD  NO RETARD  NO RETARD/RETARD
RPM PID 880-920  1430-1550  1750-2100  RPM
VSS PID 30  55  MPH
ACTUATORS/OUTPUTS - 3.0L RANGER (A/T)

Actuators/Outputs PCM Pin/PID only Measured/PID Values Units Measured/PID
KOEO Hot Idle 30 MPH 55 MPH
SS2 1 VBAT/OFF  VBAT/OFF  VBAT/OFF  VBAT/OFF  DCV/OFF-ON
MIL 2 .1/OFF  VBAT/OFF  VBAT/OFF  VBAT/OFF  DCV/OFF-ON
PATSOUT 18 1.1  1.1  1.1  1.1  DCV
CDA (CYL1&5) 26 VBAT  VBAT  VBAT  VBAT  DCV
SS1 27 .1/ON  .1/ON  VBAT/OFF  VBAT/OFF  DCV/OFF-ON
SS4 28 VBAT/OFF  VBAT/OFF  VBAT/OFF  VBAT/OFF  DCV/OFF-ON
PATSIL 30 DCV
PATSTRT 44 DCV
EGRVR 47 VBAT/0  VBAT/0  (V)  (V)  DCV/%
CTO 48 42-48  70-90  99-115  Hz
CDB (CYL3&4) 52 VBAT  VBAT  VBAT  VBAT  DCV
SS3 53 VBAT/OFF  VBAT/OFF  .1/ON  .1/ON  DCV/OFF-ON
TCC 54 VBAT/0  VBAT/0  VBAT/0  .2-.3/80-100  DCV/%
EVAPPDC 56 0-10/0-100  0-10/0-100  0-10/0-100  Hz/%
EVAPCV 67 VBAT/0  VBAT/0  VBAT/0 (S)  VBAT/0 (S)  DCV/%
VSO 68 65  125  Hz
WAC 69 VBAT/OFF  .1/ON (A)  VBAT/OFF  VBAT/OFF  DCV/OFF-ON
INJ5 73 4-4.8  6.3-8  7-13  mS
INJ3 74 4-4.8  6.3-8  7-13  mS
INJ1 75 4-4.8  6.3-8  7-13  mS
CDC (CYL2&6) 78 VBAT  VBAT  VBAT  VBAT  DCV
TCIL 79 VBAT/OFF  VBAT/OFF  VBAT/OFF  VBAT/OFF  DCV/OFF-ON
FP 80 VBAT/0  .1/100  .1/100  .1/100  DCV/%
EPC 81 8.5/35  10.2-10.9/35-50  10.5-11/23-38  10-10.7/25-39  DCV/PSI
CFCIL 82 .1/OFF  .1/OFF  .1/OFF  .1/OFF  DCV/OFF-ON
IAC 83 VBAT/0  10.7-11.9/25-35  10-10.7/38-47 (L)  8.4-10.5/40-57 (L)  DCV/%
HTR11 93 .1/ON(P)  .1/ON  .1/ON  .1/ON  DCV/OFF-ON
HTR21 94 .1/ON(P)  .1/ON  .1/ON  .1/ON  DCV/OFF-ON
HTR12 95 .2/ON(P)  .2/ON  .2/ON  .2/ON  DCV/OFF-ON
INJ6 99 4-4.8  6.3-8  7-13  mS
INJ4 100 4-4.8  6.3-8  7-13  mS
INJ2 101 4-4.8  6.3-8  7-13  mS
FUELPW1 PID (L)  4-4.8  6.3-8  7-13  mS
FUELPW2 PID (L)  4-4.8  6.3-8  7-13  mS
LONGFT1 PID (-)20-(+)20  (-)20-(+)20  (-)20-(+)20  (-)20-(+)20  %
LONGFT2 PID (-)20-(+)20  (-)20-(+)20  (-)20-(+)20  (-)20-(+)20  %
SHRTFT1 PID (L)  (-)10-(+)10  (-)10-(+)10  (-)10-(+)10  %
SHRTFT2 PID (L)  (-)10-(+)10  (-)10-(+)10  (-)10-(+)10  %
SPARKADV PID 16-18  26-36  25-32  DEG
OTHERS - 3.0L RANGER (A/T)

Other PCM Pin/PID only Measured/PID Values Units Measured/PID
KOEO Hot Idle 30 MPH 55 MPH
KAPWR 55 VBAT  VBAT  VBAT  VBAT  DCV
VPWR 71 VBAT  VBAT  VBAT  VBAT  DCV
VREF 90 DCV
GENERIC OBD II PID VALUES - 3.0L RANGER (A/T)

NOTE: All generic OBD II readings under no load (PARK or NEUTRAL).
PID Hot Idle 2500 RPM Units
LONGFT1 (-)20-(+)20  (-)20-(+)20  %
LONGFT2 (-)20-(+)20  (-)20-(+)20  %
LOAD 17-21  27-30  %
MAF 3.7-4.8  11.5-13  G/S
SHRTFT1 (-)10-(+)10  (-)10-(+)10  %
SHRTFT2 (-)10-(+)10  (-)10-(+)10  %
SHRTFT11 (-)10-(+)10  (-)10-(+)10  %
SHRTFT12 95-100  95-100  %
SHRTFT21 (-)10-(+)10  (-)10-(+)10  %
SPARKADV 16-18  24  DEG