Pinpoint Test E: The High Beam(S) Are Always On
WARNING: This page is about a different car, the 2011 Mercury Milan, 2011 Lincoln MKZ, and 2011 Ford Fusion. However, it is still accessible from the selected car via links, so may be relevant.
NOTE:
Use the correct probe adapter(s) when making measurements. Failure to use the correct probe adapter(s) may damage the connector.
- E1 CHECK FOR DTC B1510 OR DTC B2A23
- Review the DTCs retrieved from the SJB self-test.
- Is DTC B1510 or DTC B2A23 present?
- E2 CHECK THE MULTIFUNCTION SWITCH
- Ignition OFF.
- Disconnect: Multifunction Switch C202.
- Ignition ON.
- Do the high beams continue to illuminate?
- Yes : GO to E3.
- No : INSTALL a new multifunction switch. REFER to STEERING COLUMN SWITCHES article. CLEAR the DTCs. REPEAT the self-test.
- E3 CHECK THE HIGH BEAM AND FLASH-TO-PASS REQUEST INPUT CIRCUITS FOR A SHORT TO GROUND
- Ignition OFF.
- Disconnect: SJB C2280b.
- Measure the resistance between the multifunction switch C202-6, circuit CLF17 (WH/OG), harness side and ground; and between the multifunction switch C202-4, circuit CLF27 (GN/BN), harness side and ground.
- Are the resistances greater than 10,000 ohms?
- Yes : GO to E6.
- No : REPAIR the circuit in question for a short to ground. CLEAR the DTCs. REPEAT the self-test.
- E4 CHECK THE SJB HIGH BEAM OUTPUT CIRCUIT FOR A SHORT TO VOLTAGE (FUSION OR MKZ)
- Ignition OFF.
- Disconnect: SJB C2280e.
- Ignition ON.
- Do the high beams continue to illuminate?
- Yes : REPAIR circuit CLF08 (YE/VT) for a short to voltage. TEST the system for normal operation.
- No : GO to E6.
- E5 CHECK THE SJB HIGH BEAM OUTPUT CIRCUIT FOR A SHORT TO VOLTAGE (MILAN) NOTE: If only an individual high beam is always on, install a new headlamp assembly. Refer to HEADLAMP ASSEMBLY in this service information.
- Ignition OFF.
- Disconnect: LH or RH Headlamp.
- Disconnect: SJB C2280e.
- Ignition ON.
- Measure the voltage between the LH headlamp C1021-7, circuit CLF08 (YE/VT), harness side and ground; or between the RH headlamp C1041-7, circuit CLF08 (YE/VT), harness side and ground.
- Is any voltage present?
- Yes : REPAIR circuit CLF08 (YE/VT) for a short to voltage. TEST the system for normal operation.
- No : GO to E6.
- E6 CHECK FOR CORRECT SJB OPERATION
- Disconnect all the SJB connectors.
- Check for:
- corrosion
- damaged pins
- pushed-out pins
- Connect all the SJB connectors and make sure they seat correctly.
- Operate the system and verify the concern is still present.
- Is the concern still present?
- Yes : INSTALL a new SJB. REFER to MULTIFUNCTION ELECTRONIC MODULES -- FUSION, MILAN & MKZ article. TEST the system for normal operation.
- No : The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. CLEAR the DTCs. REPEAT the self-test.